Zobrazit stránku 61
2–18
Controller and Host Concepts
Enabling Mirrored Write-Back Cache
Before configuring dual-redundant controllers and enabling mirroring, ensure the
following conditions are met:
Both controllers are configured with the same size cache, 64 MB, 128 MB,
256 MB, or 512 MB.
Diagnostics indicates that both caches are good.
Both caches have a battery present, if you have not enabled the CACHE_UPS
switch. A battery does not have to be present for either cache if you enable the
CACHE_UPS switch.
No unit errors are outstanding, for example, lost data or data that cannot be
written to devices.
Both controllers are started and configured in failover mode.
For important considerations when adding or replacing DIMMs in a mirrored cache
configuration, refer to the HSG80 Array Controller ACS Version 8.3 and 8.4
Maintenance and Service Guide.