HSG80 Array Controller ACS Version 8.4Configuration and CLI Reference GuideFirst Edition (April, 1999)Part Number EK-HSG84-RG. A01/118619-001Compaq Co

Strany 2

x SET unit-number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–126SHOW . . . . . . . . . . .

Strany 3 - Contents

4–20 Planning Storagesets Figure 4–8. Striping and Mirroring in the Same StoragesetThe failure of a single disk drive has no effect on this stor

Strany 4 - Chapter 3

4–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCloning Data for BackupUse the CLONE utility to duplicate the d

Strany 5 - Chapter 4

4–22 Planning Storagesets Figure 4–9. CLONE Steps for Duplicating Unit MembersTo clone a single-disk unit, stripeset, or mirrorset:1. Establish

Strany 6 - Chapter 5

4–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide3. When prompted, enter the unit number of the unit you want to

Strany 7 - Chapter 6

4–24 Planning Storagesets DISK10300(size=832317) (y,n) [y] ? y MIRROR DISK10300 C_MA SET C_MA NOPOLICY SET C_MA MEMBERS=2 SET C_MA REPLACE=DISK22

Strany 8 - Chapter 7

4–25Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDISK20000(size=832317) (y,n) [y] ? y MIRROR DISK20000 C_MB SET

Strany 9

4–26 Planning Storagesets Backing Up Your Subsystem ConfigurationYour controller stores information about your subsystem configuration in its non

Strany 10 - Glossary

4–27Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSaving Subsystem Configuration Information to Multiple DisksYou

Strany 11

4–28 Planning Storagesets Displaying the Status of the Save Configuration FeatureYou can use the SHOW THIS_CONTROLLER FULL command to find out if

Strany 12

4–29Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCACHE_FLUSH_TIMER = DEFAULT (10 seconds)Mirrored Cache:Not enab

Strany 13

xiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFiguresThe HSG80 Subsystem . . . . . . . . . . . . . . . . . . .

Strany 14

4–30 Planning Storagesets Creating a Storageset MapConfiguring your subsystem will be easier if you know how the storagesets correspond to the di

Strany 15 - About This Guide

4–31Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 4–10. Storageset MapPower SupplySpare spare Spare R1R1

Strany 16 - Precautions

4–32 Planning Storagesets To create a storageset map:1. Copy the template from Figure 4–11.2. Establish a local or remote connection to one of th

Strany 17 - FCC Precautions

4–33Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 4–11. Storageset Map TemplatePower SupplyPower SupplyPo

Strany 18 - Conventions

4–34 Planning Storagesets Planning PartitionsUse partitions to divide a storageset or disk drive into smaller pieces, which can each be presented

Strany 19 - Typographical Conventions

4–35Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAn unpartitioned storage unit has more capacity than a partitio

Strany 20 - Special Notices

4–36 Planning Storagesets Choosing Switches for Storagesets and DevicesDepending upon the kind of storageset or device you are configuring, you c

Strany 21 - Related Publications

4–37Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRAIDset SwitchesYou can enable the following switches to contro

Strany 22 - About This Guide

4–38 Planning Storagesets RECONSTRUCT=NORMAL (default) balances the overall performance of the subsystem against the need for reconstructing th

Strany 23 - Revision History

4–39Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMirrorset SwitchesYou can enable the following switches to cont

Strany 24

xii CLONE Steps for Duplicating Unit Members . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–22Storageset Map . . . . . . . . . . . . . . .

Strany 25 - General Description

4–40 Planning Storagesets COPY=FAST allocates more resources to reconstructing the replacement disk drive, which may reduce the subsystem’s ove

Strany 26 - General Description

4–41Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDevice SwitchesWhen you add a disk drive or other storage devic

Strany 27 - CXO6841A

4–42 Planning Storagesets Transportable devices have these characteristics:❏ Can be interchanged with any SCSI interface that does not use the de

Strany 28

4–43Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideInitialize SwitchesYou can enable the following kinds of switch

Strany 29 - Summary of HSG80 Features

4–44 Planning Storagesets Increasing the Request RateA large chunk size (relative to the average request size) increases the request rate by allo

Strany 30

4–45Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideIncreasing the Data Transfer RateA small chunk size relative to

Strany 31

4–46 Planning Storagesets Maximum Chunk Size for RAIDsetsDo not exceed the chunk sizes shown in Table 4–5 for a RAIDset. (The maximum chunk size

Strany 32 - Controller Components

4–47Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide SAVE_CONFIGURATION allows the controller to use 256K of each

Strany 33 - Cabling (Continued)

4–48 Planning Storagesets If you previously configured storagesets with the SAVE_CONFIGURATION option, you do not need to initialize them again

Strany 34

4–49Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDestroy/NodestroySpecify whether to destroy or retain the user

Strany 35 - Operator Control Panel

xiiiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTablesKey to Figure 1–1 The HSG80 Subsystem . . . . . . . . .

Strany 37 - Configuration Utility

5–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 5Configuring an HSG80 Array ControllerThis chapter expla

Strany 38 - Device Statistics Utility

5–2 Configuring an HSG80 Array Controller Figure 5–1. Configuration ProcessSingle ControllerTransparent Failover ModeMultiple-Bus Failover Mode“

Strany 39 - Cache Module

5–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideIntroductionUnless you specifically requested a preconfigured su

Strany 40

5–4 Configuring an HSG80 Array Controller Configuring and Cabling an HSG80 Array ControllerYou can use these procedures to configure and cable yo

Strany 41 - External Cache Battery

5–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTipsAs you configure the controller, keep these points in mind:

Strany 42 - Charging Diagnostics

5–6 Configuring an HSG80 Array Controller Configuring a Single ControllerFollow these steps to configure an HSG80 array controller:NOTE: This pr

Strany 43 - Battery Hysteresis

5–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide7. Set the time on the controller, which provides a baseline for

Strany 44

5–8 Configuring an HSG80 Array Controller Connecting a Single Controller to the HostFor a detailed description of the controller and cables, see

Strany 45 - Controller and Host Concepts

5–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideBefore cabling, note the following: Ports❏ The active ports are

Strany 46 - Terminology

xiv Key to Figure 5–7 Example Cabling in Multiple-Bus Failover:Configuration 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 47 - ➁ This controller

5–10 Configuring an HSG80 Array Controller Using One SwitchFigure 5–3. Example Cabling for a Single Configuration using One SwitchCXO6880A15324T

Strany 48

5–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideBefore cabling, note the following: Ports❏ The active ports ar

Strany 49 - Selecting a Failover Mode

5–12 Configuring an HSG80 Array Controller Configuring in Transparent Failover ModeYou can configure dual-redundant controllers to your hosts wit

Strany 50 - Shared Port IDs

5–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide7. Put “this controller” into transparent failover mode. Use th

Strany 51 - Separate Port IDs

5–14 Configuring an HSG80 Array Controller 11. Enter any other optional CLI commands for your configuration. See “Optional Steps,” page 5–29 and

Strany 52 - Preferring the Host Path

5–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 5–4. Example Cabling in Transparent Failover using Two

Strany 53 - Caching Techniques

5–16 Configuring an HSG80 Array Controller The following steps show how to connect a pair of dual-redundant controllers to the host using two swi

Strany 54 - Write-Back Caching

5–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide5. Connect the host bus cable between the switches and the host

Strany 55 - Nonvolatile Memory

5–18 Configuring an HSG80 Array Controller Figure 5–5. Example Cabling for Transparent Failover with One SwitchCXO6836A1264355Table 5–4. Figure

Strany 56

5–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThe following steps show how to connect a pair of dual-redundan

Strany 57

xvCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAbout This GuideThis book describes the features of the HSG80 arr

Strany 58

5–20 Configuring an HSG80 Array Controller Configuring in Multiple-Bus Failover ModeIMPORTANT: If you are using HSG80 ACS V8.4P code, see the Da

Strany 59

5–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide6. On OpenVMS hosts only, change the SCSI version to SCSI-3 mod

Strany 60

5–22 Configuring an HSG80 Array Controller 11. Set up the battery discharge timer:a. Start Frutil using the following command:RUN FRUTILFrutil di

Strany 61

5–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideConnecting in Multiple-Bus Failover Mode to the HostsIMPORTANT:

Strany 62

5–24 Configuring an HSG80 Array Controller Figure 5–6. Example Cabling in Multiple-Bus Failover: Configuration 1CXO6838A12436655Table 5–5. Key

Strany 63 - Chapter 3

5–25Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideBefore cabling, note the following: Ports❏ All ports are activ

Strany 64 - Bus Dynamics

5–26 Configuring an HSG80 Array Controller 7. Turn on the subsystem.Some operating systems may require you to start the host to see the devices a

Strany 65 - Controller Device Bus

5–27Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideBefore cabling, note the following: Ports❏ All ports are activ

Strany 66 - Containers and Storagesets

5–28 Configuring an HSG80 Array Controller 5. Connect the host bus cable between the switches and the host adapters.IMPORTANT: Cables going into

Strany 67 - Containers

5–29Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideOptional StepsFollowing are some of the more common steps that

Strany 68 - Addressing

xvi About This Guide PrecautionsFollow these precautions when carrying out the procedures in this book.Electrostatic Discharge PrecautionsStatic

Strany 69

5–30 Configuring an HSG80 Array Controller Figure 5–8. SCSI Target ID Numbers on the Controller Device Bus and PVA Settings in an Extended Subsy

Strany 70

5–31Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSetting a Port OfflineNOTE: By default, all ports are online a

Strany 71 - Disk 20000 Disk 30000

5–32 Configuring an HSG80 Array Controller Changing the Host Default ValueBy default, the host is Windows NT. However, when two or more of the sa

Strany 72 - Failover Mode

5–33Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideEstablishing a Local Connection to the ControllerYou can commun

Strany 73

5–34 Configuring an HSG80 Array Controller Figure 5–9. Terminal to Local-Connection Port Connection CXO6476B1 2 3 4 5 621Table 5–7. K

Strany 74 - CXO6454B

5–35Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCAUTION: The local-connection port described in this book gene

Strany 75 - Assigning Unit Offsets

5–36 Configuring an HSG80 Array Controller Shutting Down Your SubsystemFollow these steps to shut down your StorageWorks subsystem:1. On the host

Strany 76 - Assigning Access Paths

5–37Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRestarting Your SubsystemFollow these steps to restart your sub

Strany 78

6–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 6Configuring StoragesetsThis chapter shows you how to co

Strany 79

xviiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMaintenance Port PrecautionsThe maintenance port generates, use

Strany 80

6–2 Configuring StoragesetsConfiguring Storagesets with CLI CommandsOne method of configuring storagesets is manual configuration. This method all

Strany 81 - Planning Storagesets

6–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAdding Disk DrivesThe factory-installed devices in your StorageW

Strany 82

6–4 Configuring Storagesets If the power fails or the bus is reset while HSUTIL is formatting a disk drive, the drive may become unusable. To min

Strany 83 - Disk drives

6–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide2. DEVICE_CODE_LOAD_DISK3. DEVICE_CODE_LOAD_TAPEENTER FUNCTION N

Strany 84

6–6 Configuring StoragesetsConfiguring a StripesetSee “Using Striped Mirrorsets for Highest Performance and Availability,” page 4–19, for informat

Strany 85

6–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThe following example shows the commands you would use to create

Strany 86

6–8 Configuring Storagesets1–9999. Usually, this number is the same as the unit number set in step 3.SET unit-number identifier=nnnn4. Verify the

Strany 87

6–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide2. Initialize the RAIDset. Optional: If you want to set the Init

Strany 88 - Choosing a Storageset Type

6–10 Configuring StoragesetsChapter 7, “CLI Commands,” contains more information on valid switches and values for configuring a RAIDset.Configurin

Strany 89 - CXO5507A

6–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide6. Verify the unit configuration and switches. Use the followin

Strany 90

xviii About This Guide Attention!Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des interférences

Strany 91

6–12 Configuring StoragesetsConfiguring a Single-Disk UnitFollow these steps to use a single disk drive as a single-disk unit in your subsystem:1.

Strany 92

6–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuidePartitioning a Storageset or Disk DriveSee “Planning Partitions

Strany 93

6–14 Configuring StoragesetsUse the following command to present partitions to the host:ADD UNIT unit-number storageset-name PARTITION=partition-n

Strany 94

6–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD UNIT D1 Raid1 PARTITION=1ADD UNIT D2 Raid1 PARTITION=2ADD U

Strany 95 - ➁ First member of Mirrorset 2

6–16 Configuring Storagesets2. Verify the contents of the spareset using the following command:SHOW SPARESETExampleThe following example shows the

Strany 96 - Availability

6–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExampleThe following example shows the commands you would use t

Strany 97 - I/O Request

6–18 Configuring StoragesetsDeleting a StoragesetIf the storageset you are deleting is partitioned, you must delete each partitioned unit before y

Strany 98

6–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChanging Switches for a Storageset or DeviceYou can optimize a

Strany 99 - Performance and Availability

6–20 Configuring StoragesetsChanging Initialize SwitchesThe Initialize switches cannot be changed without destroying the data on the storageset or

Strany 100 - Stripeset

6–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideConfiguring with the Command Console LUNThe Command Console LUN

Strany 101 - Cloning Data for Backup

xixCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTypographical ConventionsConvention MeaningALLCAPS Command synt

Strany 102 - Planning Storagesets

6–22 Configuring StoragesetsTo turn it off, use the following command:SET THIS_CONTROLLER NOCOMMAND_CONSOLE_LUNCAUTION: Disabling the CCL while S

Strany 103

6–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMultiple-Bus FailoverIf SET MULTIBUS_FAILOVER is enabled, all p

Strany 104

6–24 Configuring StoragesetsCAUTION: Selecting SCSI-3 mode enables access to the CCL by all hosts. If the hosts access the CCL simultaneously, un

Strany 105

6–25Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMoving StoragesetsYou can move a storageset from one subsystem

Strany 106

6–26 Configuring StoragesetsUse the following procedure to move a storageset while maintaining the data it contains:1. Show the details for the st

Strany 107 - INITIALIZE DISK

6–27Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide7. Add again each disk drive to the controller’s list of valid

Strany 108

6–28 Configuring Storagesets(...move the disk drives to their new location...)ADD DISK DISK20000 2 0 0ADD DISK DISK30000 3 0 0ADD DISK DISK40000 4

Strany 109

7–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 7CLI CommandsCommand Line Interpreter (CLI) commands all

Strany 110 - Creating a Storageset Map

7–2 CLI Commands CLI OverviewThe Command Line Interpreter (CLI) is one of the user interfaces through which you control your StorageWorks array c

Strany 111 - M1 M1 M2 M2

7–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCommand OverviewThe CLI consists of six basic command types: Co

Strany 112

While Compaq Computer Corporation believes the information included in this publication is correct as of the date of publication, it is subject to cha

Strany 113

xx About This Guide Special NoticesThis book doesn’t contain detailed descriptions of standard safety procedures. However, it does contain warnin

Strany 114 - Planning Partitions

7–4 CLI Commands Entering CLI CommandsUse the following tips and techniques when entering CLI commands: Commands are not case sensitive. For mo

Strany 115 - Disk Drives

7–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChanging the CLI PromptYou can change the CLI prompt that displa

Strany 116 - Changing Switches

7–6 CLI Commands ADD CONNECTIONSAdds the specified host connection to the table of known connections. This table is maintained in NVRAM. The maxi

Strany 117 - RAIDset Switches

7–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTE: The default connection name is assigned automatically by

Strany 118 - Membership

7–8 CLI Commands In transparent failover mode and normal mode, host connections on controller port 1 have an offset of 0 and host connections on

Strany 119 - Mirrorset Switches

7–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExamplesThis will add to the table of known connections, an entr

Strany 120 - Read Source

7–10 CLI Commands ADD DISKNames a disk drive and adds it to the controller’s configuration.NOTE: The controller supports a maximum of 72 storage

Strany 121 - Device Switches

7–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSwitchesNOTRANSPORTABLE (Default)TRANSPORTABLEIndicates whether

Strany 122 - Device Transfer Rate

7–12 CLI Commands ExamplesTo add DISK10000 at port 1, target 0, LUN 0, type:ADD DISK DISK10000 1 0 0To add DISK40200 as a transportable disk driv

Strany 123 - Initialize Switches

7–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD MIRRORSETNames a mirrorset and adds it to the controller co

Strany 124 - Increasing the Request Rate

xxiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRelated PublicationsThe following table lists some of the docume

Strany 125 - CXO-5172A-MC

7–14 CLI Commands Specify COPY=FAST to allow the creation of mirrored data to take precedence over other controller operations. When you specify

Strany 126 - Save Configuration

7–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify the READ_SOURCE=disk-name of a specific member to which

Strany 127

7–16 CLI Commands See alsoADD DISKADD UNITDELETE container-nameINITIALIZEMIRRORREDUCESHOW mirrorset-nameSHOW MIRRORSETSSHOW STORAGESETSUNMIRROR

Strany 128 - Configurations

7–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD RAIDSETNames a RAIDset and adds the RAIDset to the controll

Strany 129 - Destroy/Nodestroy

7–18 CLI Commands SwitchesPOLICY=BEST_FITPOLICY=BEST_PERFORMANCE (Default)NOPOLICYSet the selection criteria the controller uses to choose a repl

Strany 130

7–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify NORMAL to balance other controller operations with the

Strany 131 - Chapter 5

7–20 CLI Commands ADD UNIT D70 RAID8This example shows how you can create a three-member RAIDset from the members of a reduced four-member RAIDse

Strany 132

7–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD REMOTE_COPY_SETSIMPORTANT: This command works in a remote

Strany 133 - Introduction

7–22 CLI Commands The combined initiator unit-name target path-name must be typed as follows: initiator unit name controller pair name\remote un

Strany 134 - Controller

7–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD SPARESETAdds a disk drive to the spareset.SyntaxADD SPARESE

Strany 135

xxii About This Guide Compaq StorageWorks RA8000/ESA12000 HSG80 V8.x Quick Setup Guidefor OpenVMSfor DIGITAL UNIXfor Windows NT Server - IntelAA-

Strany 136 - Maintenance and Service Guide

7–24 CLI Commands ADD STRIPESETNames a stripeset and adds it to the controller configuration. Stripesets are sometimes referred to as RAID level

Strany 137 - SHOW THIS_CONTROLLER FULL

7–25Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExamplesTo create a stripeset named STRIPE1 with three disks: D

Strany 138 - Switches

7–26 CLI Commands See alsoADD UNITADD MIRRORSETDELETE container-nameINITIALIZESHOW STORAGESETSHOW STRIPESETSHOW stripeset-name

Strany 139

7–27Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideADD UNITCreates a logical unit from a device, container, or par

Strany 140 - Using One Switch

7–28 CLI Commands In transparent failover mode, adding unit D0 creates a logical unit and presents it as D0 to the host on port 1. Adding unit D1

Strany 141

7–29Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTE: Regardless of the storageset type, you cannot specify RU

Strany 142

7–30 CLI Commands If you enable another host ID, previously enabled hosts are not disabled. The new IDs are added. If you wish to enable only cer

Strany 143

7–31Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuidePREFERRED_PATH=OTHER_CONTROLLERPREFERRED_PATH=THIS_CONTROLLERNO

Strany 144

7–32 CLI Commands READ_CACHE (Default)NOREAD_CACHESets the controller’s cache read policy function. Read caching improves performance in almost a

Strany 145

7–33Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideWRITE_PROTECT NOWRITE_PROTECT (Default)Tells the controller whe

Strany 146

xxiiiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRevision HistoryThis is a new document.

Strany 147

7–34 CLI Commands ExamplesThis example shows how to create unit D102 from a single-disk drive named DISK10000 and sets the host’s access to the u

Strany 148

7–35Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCLEAR_ERRORS CLIStops the display of current or previous error

Strany 149

7–36 CLI Commands CLEAR_ERRORS controller INVALID_CACHEClears an invalid cache error and allows the controller and cache to resume operation. If

Strany 150

7–37Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify DESTROY_UNFLUSHED_DATA to retain the controller informa

Strany 151 - IDENTIFIER

7–38 CLI Commands See alsoCLEAR_ERRORS CLICLEAR_ERRORS LOST_DATACLEAR_ERRORS UNKNOWNCLEAR_ERRORS UNWRITEABLE_DATA

Strany 152

7–39Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCLEAR_ERRORS device-name UNKNOWNIf a device failure causes the

Strany 153

7–40 CLI Commands CLEAR_ERRORS unit-number LOST_DATAClears lost data errors on a unit; all partitions on the unit’s container are affected.The co

Strany 154

7–41Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSee alsoCLEAR_ERRORS CLICLEAR_ERRORS INVALID_CACHECLEAR_ERRORS

Strany 155

7–42 CLI Commands CLEAR_ERRORS unit-number UNWRITEABLE_DATAClears an unwriteable data error on a unit. It affects all partitions on the same cont

Strany 156

7–43Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSee alsoCLEAR_ERRORS CLICLEAR_ERRORS INVALID_CACHECLEAR_ERRORS

Strany 158

7–44 CLI Commands CONFIGURATION RESETErases the entire configuration on “this controller,” restores the controller’s default configuration, and s

Strany 159 - Optional Steps

7–45Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCONFIGURATION RESTORECopies a controller’s configuration from t

Strany 160 - Extended Subsystem

7–46 CLI Commands SyntaxCONFIGURATION RESTORE See alsoCONFIGURATION RESETCONFIGURATION SAVEINITIALIZE

Strany 161 - Backing Up Power with a UPS

7–47Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCONFIGURATION SAVEForces a current copy of configuration inform

Strany 162

7–48 CLI Commands CREATE_PARTITIONDivides a non-transportable disk drive storageset into several, separately-addressable storage units. The comma

Strany 163

7–49Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTo create a partition, specify a percentage of the container’s

Strany 164 - CXO6476B

7–50 CLI Commands ADD DISK DISK10000 1 0 0ADD DISK DISK20100 2 1 0ADD DISK DISK30200 3 2 0ADD RAIDSET RAID9 DISK10000 DISK20100 DISK30200INITIALI

Strany 165

7–51Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDELETE connectionsDeletes a host connection entry from the tabl

Strany 166 - Shutting Down Your Subsystem

7–52 CLI Commands ExamplesDeletes the host connection Server1 from the table of known connections (unless the access path to Server1 is specifica

Strany 167 - Restarting Your Subsystem

7–53Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDELETE container-name Deletes a container belonging to the cont

Strany 168

1–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 1General DescriptionThis chapter illustrates and describ

Strany 169 - Configuring Storagesets

7–54 CLI Commands ExamplesTo delete a disk drive named DISK10000, type:DELETE DISK10000To delete a stripeset named STRIPE1, enter:DELETE STRIPE1T

Strany 170 - Unit Switches

7–55Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDELETE FAILEDSETRemoves a disk drive from the failedset. The fa

Strany 171 - Formatting Disk Drives

7–56 CLI Commands DELETE SPARESETRemoves a disk drive from the spareset.SyntaxDELETE SPARESET disk-nameParameterdisk-nameIdentifies the disk driv

Strany 172 - Configuring Storagesets

7–57Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDELETE unit-number Deletes a logical unit from the controller c

Strany 173

7–58 CLI Commands DESTROY_PARTITIONMarks the area reserved for a partition as available. The freed area is then consolidated with any adjacent fr

Strany 174 - Configuring a Stripeset

7–59Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExampleThe following example shows how to delete the unit for p

Strany 175 - Configuring a Mirrorset

7–60 CLI Commands DIRECTORYLists the diagnostics and utilities available on “this controller.”SyntaxDIRECTORYExampleThe example below shows how t

Strany 176 - Configuring a RAIDset

7–61Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideHELP Displays a brief explanation of how to use the question ma

Strany 177 - RAIDset-name

7–62 CLI Commands INITIALIZEInitializes or destroys metadata on a container. During initialization, a small amount of disk space is reserved for

Strany 178

7–63Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideParameterscontainer-nameSpecifies the container to initialize.

Strany 179

1–2 General Description The HSG80 Array Controller SubsystemTake a few moments to familiarize yourself with the major components of the HSG80 arr

Strany 180

7–64 CLI Commands The default chunk size for storagesets with less than 9 members is 256 blocks, or 128 kilobytes (K). The default chunk size for

Strany 181

7–65Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify SAVE_CONFIGURATION to store a copy of the controller co

Strany 182

7–66 CLI Commands SHOW DEVICES FULLName Type Port Targ Lun Used by-----------------------------------------

Strany 183

7–67Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideLOCATEIndicates the physical location of configured units, stor

Strany 184

7–68 CLI Commands PTL (SCSI-location)Causes the device fault LED on the device at the given SCSI location to flash. See “Mapping the Physical Dev

Strany 185 - Enabling Autospare

7–69Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThis example shows how to cause the device fault LEDs on all of

Strany 186 - Deleting a Storageset

7–70 CLI Commands MIRRORCreates a one-member mirrorset from a single disk. This command is used only on disks configured as units or members of a

Strany 187 - Changing Device Switches

7–71Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSwitchesCOPY=FASTCOPY=NORMAL (Default)Sets the speed at which t

Strany 188 - Changing Unit Switches

7–72 CLI Commands Specify NOPOLICY to prevent the controller from automatically replacing a failed disk device. This causes the mirrorset to oper

Strany 189

7–73Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSee alsoADD MIRRORSETREDUCESHOW MIRRORSETSUNMIRROR

Strany 190 - SCSI-2 and SCSI-3 Modes

1–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 1–1. The HSG80 Subsystem12438 7 7 916131415121110CXO6841

Strany 191 - Transparent Failover

7–74 CLI Commands POWEROFFPowers off all disk units in a cabinet and turns off the cabinet power.SyntaxPOWEROFFSwitchesBATTERY _ONBATTERY_OFF (De

Strany 192 - SCSI-3 Mode

7–75Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSECONDS=nnAs soon as the POWEROFF command is entered, all disk

Strany 193 - Moving Storagesets

7–76 CLI Commands In dual-redundant mode, if both controllers can’t be shutdown, then both controllers and their batteries’ chargers remain on.Ex

Strany 194

7–77Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideREDUCERemoves member disk drives from mirrorsets and decreases

Strany 195 - Name Storageset Uses Used by

7–78 CLI Commands For each reduced mirrorset, there must be at least one remaining normal member after the reduction. If this is not true for all

Strany 196

7–79Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideName Storageset Uses U

Strany 197 - CLI Commands

7–80 CLI Commands RENAMERenames a specified container or a specified host connection.SyntaxRENAME old-name new-nameParametersold-nameSpecifies th

Strany 198 - CLI Overview

7–81Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRESTART controllerFlushes all user data from the specified cont

Strany 199 - Getting Help

7–82 CLI Commands IMMEDIATE_SHUTDOWNNOIMMEDIATE_SHUTDOWN (Default)Instructs the controller whether to flush the write-back cache or not.CAUTION:

Strany 200 - Entering CLI Commands

7–83Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRETRY_ERRORS UNWRITEABLE_DATACauses the controller to attempt t

Strany 201 - Command Syntax

1–4 General Description Table 1–1. Key to Figure 1–1 The HSG80 SubsystemItem Description1 BA370 rack-mountable enclosure2 Cooling fan3 Power cab

Strany 202 - ADD CONNECTIONS

7–84 CLI Commands RUNRuns a diagnostic or utility program on “this controller.” Diagnostic and utility programs only run on “this controller.”Syn

Strany 203

7–85Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCAUTION: Run the DILX utility in the autoconfigure mode only a

Strany 204 - CLI Commands

7–86 CLI Commands ExampleThis example shows how to start the DILX diagnostic program:RUN DILX...See alsoDIRECTORY

Strany 205 - See also

7–87Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSELFTEST controllerFlushes the data from the specified controll

Strany 206 - ADD DISK

7–88 CLI Commands IMMEDIATE_SHUTDOWNNOIMMEDIATE_SHUTDOWN (Default)Instructs the controller whether to flush the write-back cache or not.CAUTION:

Strany 207

7–89Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET connection-nameChanges the operating characteristics of a h

Strany 208

7–90 CLI Commands Unit number = the number assigned to the unit in the ADD UNIT command. This is the number by which the unit is known interna

Strany 209 - ADD MIRRORSET

7–91Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET controller Changes parameters on the specified controller.N

Strany 210

7–92 CLI Commands Table 7–4. SET controller SwitchesSwitch ValuesALLOCATION_CLASS 0-4294967295In DIGITAL Open VMS, do not specify a number over

Strany 211

7–93Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSCSI_VERSION SCSI-2 (default)SCSI-3TERMINAL_PARITYNOTERMINAL_PA

Strany 212

1–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSummary of HSG80 FeaturesTable 1–2 summarizes the features of th

Strany 213 - ADD RAIDSET

7–94 CLI Commands ALLOCATION_CLASSAllocation class is a unique identification number assigned to the controller pair under certain operating syst

Strany 214

7–95Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCAUTION: Setting CACHE_UPS without having a UPS or similar bac

Strany 215

7–96 CLI Commands MIRRORED_CACHENOMIRRORED_CACHE (Default)Enables the mirrored-write-back-data cache feature on dual-redundant controllers. When

Strany 216

7–97Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNODE_ID=nnnn-nnnn-nnnn-nnnn checksumSets the subsystem worldwid

Strany 217 - ADD REMOTE_COPY_SETS

7–98 CLI Commands PORT_1_TOPOLOGY=FABRICPORT_2_TOPOLOGY=FABRICUsed only in switch (FC-SW) topology.Specifies switch topology for a host port.PROM

Strany 218

7–99Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideIt also specifies how the command console LUN is handled. The c

Strany 219 - ADD SPARESET

7–100 CLI Commands ExamplesThis example shows how to change the other controller’s CLI prompt:SET OTHER_CONTROLLER PROMPT=CONTROLLER “B”This exam

Strany 220 - ADD STRIPESET

7–101Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET device-nameChanges the transportable characteristics and t

Strany 221

7–102 CLI Commands Storagesets cannot be made transportable. Specify NOTRANSPORTABLE for all disks used in RAIDsets, stripesets, mirrorsets, and

Strany 222

7–103Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET EMUSets operating parameters for the environmental monitor

Strany 223 - ADD UNIT

iiiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideContentsAbout This GuideGetting Help. . . . . . . . . . . . . .

Strany 224

1–6 General Description Host bus interconnect Optical: MultiMode 50 Micron(Do not mix media types) Gigabit Link Module (GLM)Device protocol SCSI

Strany 225

7–104 CLI Commands If any of the setpoints assigned to a slave EMU do not match the corresponding setpoints assigned to the master EMU, the slave

Strany 226

7–105Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSelect FANSPEED=AUTOMATIC to allow the EMU to control the fan

Strany 227

7–106 CLI Commands SET FAILEDSETChanges the automatic replacement policy for the failedset.SyntaxSET FAILEDSET SwitchesAUTOSPARENOAUTOSPARESpecif

Strany 228

7–107Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThese steps use DISK10000 as an example.1. Delete all containe

Strany 229

7–108 CLI Commands SET FAILOVERConfigures both controllers to operate in a dual-redundant, transparent failover, configuration. This allows both

Strany 230

7–109Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExampleThis example shows how to set the controllers in a dual

Strany 231 - CLEAR_ERRORS CLI

7–110 CLI Commands SET mirrorset-name Changes the characteristics of a mirrorset, including the addition and removal of members.SyntaxSET mirrors

Strany 232 - INVALID_CACHE

7–111Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTE: No other switches can be set when you specify the MEMBE

Strany 233

7–112 CLI Commands NOTE: Normalizing members exist only when you first create a mirrorset or when you clear lost data on a mirrored unit. The co

Strany 234

7–113Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify POLICY=BEST_PERFORMANCE to choose a replacement disk d

Strany 235 - UNKNOWN

1–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMaximum number of RAID-5, RAID-1, and RAID-0 storagesets 45Maxim

Strany 236 - LOST_DATA

7–114 CLI Commands This example shows how to remove member DISK30000 from mirrorset MIRR1 created above. If the mirrorset has a replacement polic

Strany 237

7–115Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET MULTIBUS_FAILOVERPlaces “this controller” and the “other c

Strany 238 - UNWRITEABLE_DATA

7–116 CLI Commands Due to the amount of information being passed from one controller to the other, this command may take up to one minute to comp

Strany 239

7–117Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET NOFAILOVERReconfigures both controllers to operate in a no

Strany 240 - CONFIGURATION RESET

7–118 CLI Commands Specify NODESTROY_UNFLUSHABLE_DATA to leave the unwritten data intact in the failed controller’s write-back cache. When the fa

Strany 241 - CONFIGURATION RESTORE

7–119Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET NOMULTIBUS_FAILOVERReconfigures both controllers to operat

Strany 242

7–120 CLI Commands Under some circumstances, the data in a failed controller’s write-back cache may not fail over to the operating controller’s w

Strany 243 - CONFIGURATION SAVE

7–121Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSET RAIDset-name Changes the characteristics of a RAIDset.Synt

Strany 244 - CREATE_PARTITION

7–122 CLI Commands RECONSTRUCT=FASTRECONSTRUCT=NORMAL (Default)Sets the speed at which the controller reconstructs the data on the new RAIDset me

Strany 245

7–123Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideREPLACE=disk-nameInstructs the controller to add a disk member

Strany 246

1–8 General Description Controller ComponentsFigure 1–2 details the HSG80 Array Controller and its Fibre Channel optical components.Figure 1–2.

Strany 247 - Parameters

7–124 CLI Commands SET remote-copy-set-nameIMPORTANT: This command works in a remote copy environment only using HSG80 ACS V8.4P code, where loc

Strany 248

7–125Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSelect NORMAL to unlock the remote copy center and to change t

Strany 249

7–126 CLI Commands SET unit-numberChanges the characteristics of a unit.SyntaxSET unit-numberParameterunit-numberSpecifies the logical unit numbe

Strany 250

7–127Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTE: Regardless of storageset type, the RUN and NORUN switch

Strany 251 - DELETE FAILEDSET

7–128 CLI Commands If you enable another host ID, previously enabled hosts are not disabled. The new ID is added. If you wish to enable only cert

Strany 252 - DELETE SPARESET

7–129Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuidePREFERRED_PATH=OTHER_CONTROLLERPREFERRED_PATH=THIS_CONTROLLERN

Strany 253 - Parameter

7–130 CLI Commands Read caching improves performance in almost all situations, so it is generally recommended to leave it enabled. However, under

Strany 254 - DESTROY_PARTITION

7–131Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSpecify WRITE_PROTECT to prevent host write operations to the

Strany 255

7–132 CLI Commands ExampleThis example shows how to enable write protect and turn off the read cache on unit D102:SET D102 WRITE_PROTECT NOREAD_C

Strany 256 - DIRECTORY

7–133Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSHOWDisplays information about controllers, storagesets, devic

Strany 257

1–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTE: To view an optional maintenance port cable and its compon

Strany 258

7–134 CLI Commands THIS_CONTROLLEROTHER_CONTROLLERdevice-nameSpecifies the name of a particular device to be displayed. For example, SHOW DISK201

Strany 259

7–135Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guideunit-numberSpecifies the name of a particular unit to be displ

Strany 260

7–136 CLI Commands ExamplesThis example shows how to display a listing of disks:SHOW DISKSName Type Port Targ Lun Used by --

Strany 261

7–137Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThis example shows how to display a complete listing of the mi

Strany 262

7–138 CLI Commands This example shows the full information for a controller:SHOW THIS_CONTROLLER FULLController:HSG80 (C) DEC CX00001905 Softw

Strany 263

7–139Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCACHE_FLUSH_TIMER = DEFAULT (10 seconds)Mirrored Cache:Not ena

Strany 264

7–140 CLI Commands SHUTDOWN controllerFlushes all user data from the specified controller’s write-back cache (if present) and shuts down the cont

Strany 265 - LOCATE CANCEL

7–141Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideIMMEDIATE_SHUTDOWNNOIMMEDIATE_SHUTDOWN (Default)Instructs the

Strany 266

7–142 CLI Commands UNMIRRORConverts a one-member mirrorset back to a non-mirrored disk drive and deletes its mirrorset from the list of known mir

Strany 267

A–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAppendix ASystem ProfilesThis appendix contains device and stora

Strany 268

1–10 General Description Controller ComponentsThe HSG80 Array Controller components that you will use most often, such as the maintenance port an

Strany 269

A–2 System Profiles Device ProfileType of DeviceDevice SwitchesInitialize SwitchesUnit Switches___ Platter disk drive ___ Optical disk drive ___ Tape

Strany 270 - POWEROFF

A–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideStorageset ProfileType of storagesetPartitionsRAIDset SwitchesMi

Strany 271

A–4 System Profiles Enclosure TemplatePower SupplyPower SupplyPower SupplyPower SupplyPower SupplyPower SupplyPower SupplyPower Supply

Strany 272

B–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAppendix BController SpecificationsThis chapter contains physica

Strany 273

B–2 Controller Specifications Physical and Electrical Specifications for the ControllerTable B–1 lists the physical and electrical specifications for

Strany 274

B–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideEnvironmental SpecificationsThe HSG80 array controller is intend

Strany 275

B–4 Controller Specifications Table B–3 Maximum Operating Environmental SpecificationsCondition SpecificationTemperature +10° to +40°C (+50° to +104°

Strany 276

GL–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideGlossary This glossary defines terms pertaining to the HSG80 Fi

Strany 277 - RESTART

GL–2 Glossary array controller softwareAbbreviated ACS. Software contained on a removable ROM program card that provides the operating system for the

Strany 278

GL–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidebuilt-in self-test A diagnostic test performed by the array con

Strany 279 - RETRY_ERRORS UNWRITEABLE_DATA

1–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideOperator Control Panel The operator control panel (OCP) co

Strany 280

GL–4 Glossary command line interpreterThe configuration interface to operate the controller software.configuration file A file that contains a repres

Strany 281

GL–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidedata striping The process of segmenting logically sequential da

Strany 282

GL–6 Glossary dual-simplex A communications protocol that allows simultaneous transmission in both directions in a link, usually with no flow control

Strany 283 - SELFTEST

GL–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidefailedset A group of failed mirrorset or RAIDset devices automa

Strany 284

GL–8 Glossary FCC Class B This certification label appears on electronic devices that can be used in either a home or a commercial environment within

Strany 285

GL–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidefull duplex (adj) Pertaining to a communications method in whic

Strany 286

GL–10 Glossary hot disks A disk containing multiple hot spots. Hot disks occur when the workload is poorly distributed across storage devices which p

Strany 287

GL–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideI/O interfaceSee interface.I/O module A 16-bit SBB shelf devic

Strany 288 - Switches

GL–12 Glossary local terminal A terminal plugged into the EIA-423 maintenance port located on the front bezel of the controller. See also maintenance

Strany 289 - Switches (Continued)

GL–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidemaintenance terminalAn EIA-423-compatible terminal used with t

Strany 290

1–12 General Description After you configure your controller, you should periodically check its control panel. If an error occurs, one or more of

Strany 291

GL–14 Glossary not permitted to arbitrate or originate frames. An L_Port in non-participating mode may or may not have an AL_PA. See also participati

Strany 292

GL–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guideother controller The controller in a dual-redundant pair that

Strany 293

GL–16 Glossary parity RAIDSee RAIDset.partition A logical division of a container, represented to the host as a logical unit.peripheral device Any un

Strany 294

GL–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guideprotocol The conventions or rules for the format and timing of

Strany 295

GL–18 Glossary RAID level 3/5 A DIGITAL-developed RAID storageset that stripes data and parity across three or more members in a disk array. A RAIDse

Strany 296

GL–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guiderequest rate The rate at which requests are arriving at a serv

Strany 297

GL–20 Glossary SCSI device ID numberA bit-significant representation of the SCSI address referring to one of the signal lines, numbered 0 through 7 f

Strany 298

GL–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidestorage array subsystemSee storage subsystem.storageset (1) A

Strany 299

GL–22 Glossary striping The technique used to divide data into segments, also called chunks. The segments are striped, or distributed, across members

Strany 300

GL–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideUltra SCSI A Fast-20 SCSI bus. See also Wide Ultra SCSI.unit

Strany 301

1–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideVirtual Terminal DisplayUse the virtual terminal display (VTDPY

Strany 302 - SET FAILEDSET

GL–24 Glossary write-back caching A cache management method used to decrease the subsystem’s response time to write requests by allowing the controll

Strany 303

I–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideIndexAAC input modulepart number, 1–4Access pathsgeneral descrip

Strany 304 - SET FAILOVER

I–2 Index to spareset using CLI, 6–15Addressesproviding with the PVA module, 5–29Addressingcontroller and host, 3–1PTL convention, 3–6ALLOCATION_CLAS

Strany 305

I–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCache policiesfault-tolerance for write-back caching, 2–11Cache,

Strany 306

I–4 Index CLEAR_ERRORS controller INVALID_CACHE, 7–36CLEAR_ERRORS device-name UNKNOWN, 7–39CLEAR_ERRORS unit-number LOST_DATA, 7–40CLEAR_ERRORS un

Strany 307

I–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCONFIG, running, 7–84Configurationmodifying controller configura

Strany 308

I–6 Index controller and cache module location, 1–10displaying information, 7–133dual-redundant controller configuration, 5–14, 5–23dual-redundant co

Strany 309

I–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSECTORS_PER_TRACK, 7–49SIZE, 7–48CREATE_PARTITION container-name

Strany 310

I–8 Index Device profile, A–2Device protocol, 1–6Device statistics utility. See DSTAT utilityDevice switches, 4–36, 4–41changing switches, 4–36device

Strany 311 - SET MULTIBUS_FAILOVER

I–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidepartitions supported, 5–3removing from a mirrorset, 7–77removing

Strany 312

1–14 General Description microcode updates. Contact the Customer Service Center (CSC) for directions in obtaining the appropriate EMU microcode a

Strany 313 - SET NOFAILOVER

I–10 Index Erasing metadata, 4–49Error messagesclearing from CLI, 7–35clearing unwriteable data errors, 7–42Examplesadding disk drives to a spareset,

Strany 314

I–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guideassigning access paths, 3–14bus dynamics, 3–2connecting to the

Strany 315 - SET NOMULTIBUS_FAILOVER

I–12 Index INITIALIZE container-name, 7–62Initialize switches, 4–43chunk size, 4–43CHUNKSIZE, 4–43DESTROY, 4–49destroy/nodestroy, 4–49NODESTROY, 4–49

Strany 316

I–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideMembershipRAIDset switches, 4–38Metadataerasing, 6–17retaining,

Strany 317

I–14 Index NODESTROY, 4–49INITIALIZE, 7–64NODESTROY_UNFLUSHABLE_DATASET NOMULTIBUS_FAILOVER, 7–119NODESTROY_UNFLUSHED_DATACLEAR_ERRORS controller INV

Strany 318

I–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guidefor RAIDsets, 4–37for storage units, 6–2initialize, 4–43Other c

Strany 319

I–16 Index PORT_1_TOPOLOGYSET controller, 7–97PORT_2_ALPASET controller, 7–97PORT_2_TOPOLOGYSET controller, 7–97PortsSee also Device ports, Host port

Strany 320

I–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guideadding while missing a member, 7–19changing characteristics, 7–

Strany 321

I–18 Index NOIGNORE_ERRORS, 7–81NOIMMEDIATE_SHUTDOWN, 7–82Restarting subsystem, 5–37Restarting the subsystem, 5–37Restoring configuration, 7–45RETRY_

Strany 322

I–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOTERMINAL_PARITY, 7–99PORT_1_ALPA, 7–97PORT_1_TOPOLOGY, 7–97PO

Strany 323 - Table 7–6 SET

1–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCache ModuleEach controller requires a companion cache module a

Strany 324

I–20 Index controller behavior at restart, 7–82controller behavior at shutdown, 7–141controller behavior selftest, 7–88controller cache flush timer,

Strany 325

I–21Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideNOIMMEDIATE_SHUTDOWN, 7–141Shutting down subsystem, 5–36Shuttin

Strany 326

I–22 Index striped mirrorsets, 4–2stripesets, 4–2, 4–9See also Configuration rulesStorageWorks array controller, 7–2Striped mirrorsetunit number in O

Strany 327

I–23Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTerminology of the controller, 2–2Testing controllers, 7–87This

Strany 328

I–24 Index VTDPY, 1–13See also Config utilitySee also HSUTILTroubleshooting and maintaining the controllerutilities and exercisers, 1–12Typographical

Strany 329

I–25Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideClone utility, 1–14CONFIG utility, 1–13DILX, 1–13DSTAT, 1–14FMU

Strany 331

iv Chapter 2Controller and Host ConceptsTerminology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 332

1–16 General Description Figure 1–5. Cache ModuleTable 1–6. Key to Figure 1–5 Cache ModuleItem Description➀Cache-memory power LED button➁ECB Y

Strany 333 - SHOW MIRR1

1–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideExternal Cache BatteryTo preserve the write-back cache data in

Strany 334

1–18 General Description When the batteries are fully charged, an ECB can preserve 512 MB of cache memory for 24 hours. However, the battery capa

Strany 335 - FANSPEED AUTOMATIC

1–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideBattery HysteresisWhen charging a battery, write-back caching w

Strany 337

2–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 2Controller and Host ConceptsThis chapter provides conce

Strany 338 - UNMIRROR

2–2 Controller and Host Concepts TerminologyWhen configuring the subsystem you will encounter the following terms and concepts that you must unde

Strany 339

2–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide Other controller—the controller that you are not currently con

Strany 340 - Device Profile

2–4 Controller and Host Concepts Unresponsive and Surviving ControllersWhen a failover occurs in a dual-redundant pair of controllers, the contro

Strany 341 - Storageset Profile

2–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSelecting a Failover ModeWhen you select a failover mode, your s

Strany 342 - Enclosure Template

vCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideController and Port Worldwide Names (Node IDs). . . . . . . . . .

Strany 343

2–6 Controller and Host Concepts Shared Port IDsFigure 2–3 shows one example of a Fibre Channel Switched Fabric (FC-SW) configuration in transpar

Strany 344

2–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAs Figure 2–3 shows, only port 1 on controller A normally is act

Strany 345 - Environmental Specifications

2–8 Controller and Host Concepts Figure 2–4. Example of Separate Host Port IDs in Multiple-Bus FailoverAs Figure 2–4 shows, all ports on both co

Strany 346 - B–4 Controller Specifications

2–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCaching TechniquesThe cache module supports the following cachin

Strany 347

2–10 Controller and Host Concepts During read-ahead caching, the controller anticipates subsequent read requests and begins to prefetch the next

Strany 348 - GL–2 Glossary

2–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFault-Tolerance for Write-Back CachingThe cache module supports

Strany 349 - See also

2–12 Controller and Host Concepts Table 2–2 shows the cache policies resulting from a full or partial failure of cache module A in a dual-redunda

Strany 350 - GL–4 Glossary

2–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDIMM or cache memory controller chip failureGood Data integrity

Strany 351

2–14 Controller and Host Concepts Table 2–3 shows the cache policies resulting from full or partial failure of cache module A’s ECB in a dual-red

Strany 352 - GL–6 Glossary

2–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideTable 2–3. Resulting Cache Policies and ECB StatusECB Status C

Strany 353

vi Reconstruction Policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–37Membership . . . . . . . . . . .

Strany 354 - GL–8 Glossary

2–16 Controller and Host Concepts Failed At least 50% chargedData loss: NoCache policy: Controller A supports write-through caching only; control

Strany 355

2–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFailed Less than 50% chargedData loss: NoCache policy: Both con

Strany 356 - GL–10 Glossary

2–18 Controller and Host Concepts Enabling Mirrored Write-Back CacheBefore configuring dual-redundant controllers and enabling mirroring, ensure

Strany 357

3–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 3Controller and Host AddressingThis chapter provides a b

Strany 358 - GL–12 Glossary

3–2 Controller and Host Addressing Bus DynamicsYour controller is the intelligent bridge between your host and the devices and the logical units

Strany 359

3–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideHost BusWhen the host communicates to the controller through the

Strany 360 - GL–14 Glossary

3–4 Controller and Host Addressing Containers and StoragesetsContainers and storagesets are comprised of physical devices. The logical units are

Strany 361

3–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideThe following are the supported storagesets for the HSG80 array

Strany 362 - GL–16 Glossary

3–6 Controller and Host Addressing Logically Connecting the Storage Array to the HostThe combination of storage devices is called a storage array

Strany 363

3–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuidePlace one space between the port number, target number, and the

Strany 364 - GL–18 Glossary

viiCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideSetting a Port Offline . . . . . . . . . . . . . . . . . . . . .

Strany 365

3–8 Controller and Host Addressing Figure 3–4 PTL Addressing in a ConfigurationIn Figure 3–4, the controller addresses DISK30800 through device

Strany 366 - GL–20 Glossary

3–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideWhen your controller receives an I/O request, it identifies the

Strany 367

3–10 Controller and Host Addressing Mapping the Containers and Storagesets to the Host with Logical UnitsIn a subsystem, the host communicates to

Strany 368 - GL–22 Glossary

3–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 3–6 Controller Port ID and Unit Numbers in Transparent

Strany 369

3–12 Controller and Host Addressing Figure 3–7 Controller Port ID Numbers and Unit Numbers in Multiple-Bus Failover ModeController APort 1 (Acti

Strany 370 - GL–24 Glossary

3–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideAssigning Unit OffsetsUnit offsets are used to define the first

Strany 371

3–14 Controller and Host Addressing Assigning Access PathsDifferent operating systems may not tolerate other operating systems’ access to their u

Strany 372

3–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideController and Port Worldwide Names (Node IDs)A worldwide name—

Strany 373

3–16 Controller and Host Addressing In a subsystem with two controllers in transparent failover mode, the controller port IDs increment as follow

Strany 374

3–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideRestoring Worldwide Names (Node IDs)CAUTION: Each subsystem ha

Strany 375

viii Moving Storagesets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6–25Chapter 7CLI CommandsC

Strany 377

4–1Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideChapter 4Planning StoragesetsThis chapter takes you through the

Strany 378

4–2 Planning Storagesets IntroductionStoragesets are implementations of RAID technology, also known as a “Redundant Array of Independent Disks.”

Strany 379

4–3Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 4–1. Units Created from Storagesets, Partitions, and Dri

Strany 380

4–4 Planning Storagesets Planning and Configuring StoragesetsUse this procedure to plan and configure the storagesets for your subsystem. Use the

Strany 381

4–5Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideCreating a Storageset and Device ProfileCreating a profile for y

Strany 382

4–6 Planning Storagesets TYPE OF STORAGESETPartitionsRAIDset SwitchesMirrorset SwitchesInitialize SwitchesUnit SwitchesFigure 4–2 A Typical Stor

Strany 383

4–7Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDetermining Storage RequirementsStart the planning process by de

Strany 384

4–8 Planning Storagesets Choosing a Storageset TypeDifferent applications may have different storage requirements, so you will probably want to c

Strany 385

4–9Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFor a comprehensive discussion of RAID, refer to The RAIDBOOK—A

Strany 386

ixCompaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideDELETE container-name . . . . . . . . . . . . . . . . . . . . .

Strany 387

4–10 Planning Storagesets The relationship between the chunk size and the average request size determines if striping maximizes the request rate

Strany 388

4–11Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFor example, if the mean time between failures (MTBF) for a sin

Strany 389

4–12 Planning Storagesets Figure 4–4. Distribute Members across Device PortsTable 4–3. Key to Figure 4–4 Distribute Members across Device Ports

Strany 390

4–13Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide Stripesets contain between 2 and 24 members. Stripesets are

Strany 391

4–14 Planning Storagesets Figure 4–5. Mirrorsets Maintain Two Copies of the Same DataConsiderations for Planning a MirrorsetKeep these points in

Strany 392

4–15Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide If you’re using more than one mirrorset in your subsystem, yo

Strany 393

4–16 Planning Storagesets Place mirrorsets and RAIDsets on different ports to minimize risk in the event of a single port bus failure. Mirrors

Strany 394

4–17Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference GuideFigure 4–7. Parity Ensures Availability; Striping Provides Goo

Strany 395

4–18 Planning Storagesets The relationship between the chunk size and the average request size determines if striping maximizes the request rate

Strany 396

4–19Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide RAIDsets are particularly well-suited for the following:❏ Sma