Power-Up Diagnostics and Display 3-29
Table 3–3 RMC Warning Messages
Message Meaning
PSn failed
Power supply failed. “n” is 0, 1, or 2.
OverTemp Warning System temperature is near the high threshold.
Fann failed
Fan failed. “n” is 0 through 6.
PCI door opened Cover to PCI card cage is off. Reinstall cover.
Fan door opened Cover to main fan area (fans 5 and 6) is off. Reinstall
cover.
3.3V bulk warn Power supply voltage over or under threshold.
5V bulk warn Power supply voltage over or under threshold.
12V bulk warn Power supply voltage over or under threshold.
–12V bulk warn Power supply voltage over or under threshold.
VTERM warn Voltage regulator over or under threshold.
CTERM warn Voltage regulator over or under threshold.
CPUn VCORE warn
CPU core voltage over or under threshold. “n” is 0, 1,
2, or 3.
CPUn VIO warn
I/O voltage on CPU over or under threshold. “n” is 0,
1, 2, or 3.