Compaq AlphaServer ES40 Technické informace

Procházejte online nebo si stáhněte Technické informace pro Servery Compaq AlphaServer ES40. Compaq AlphaServer ES40 Technical information Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 444
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Compaq Computer Corporation
AlphaServer ES40
Service Guide
Order Number: EK–ES240–SV. A01
This guide is intended for service providers and self-
maintenance customers responsible for Compaq AlphaServer
ES40 systems.
Zobrazit stránku 0
1 2 3 4 5 6 ... 443 444

Shrnutí obsahu

Strany 1 - AlphaServer ES40

Compaq Computer CorporationAlphaServer ES40Service GuideOrder Number: EK–ES240–SV. A01This guide is intended for service providers and self-maintenanc

Strany 2

xD.4 Cbox Read Register...D-8D.5 Exception Address Register (EXC_ADDR)...

Strany 3

3-32 Compaq AlphaServer ES40 Service Guide3.5 Forcing a Fail-Safe Floppy LoadUnder some circumstances, you may need to force the activation of theF

Strany 4

Power-Up Diagnostics and Display 3-331. Turn off the system. Unplug the power cord from each power supply andwait for the 5V AUX indicators to ext

Strany 5 - Contents

3-34 Compaq AlphaServer ES40 Service Guide3.6 Updating the RMCUnder certain circumstances, the RMC will not function. If theproblem is caused by c

Strany 6

Power-Up Diagnostics and Display 3-35You can update the remote management console firmware from flash ROMusing the LFU.1. Load the update medium.2.

Strany 8

SRM Console Diagnostics 4-1Chapter 4SRM Console DiagnosticsThis chapter describes troubleshooting with the SRM console.The SRM console firmware con

Strany 9 - Appendix D Registers

4-2 Compaq AlphaServer ES40 Service Guide4.1 Diagnostic Command SummaryDiagnostic commands are used to test the system and help diagnosefailures.

Strany 10 - Examples

SRM Console Diagnostics 4-3Table 4–1 Summary of Diagnostic and Related Commands (Continued)Command FunctionkillTerminates a specified pr

Strany 11

4-4 Compaq AlphaServer ES40 Service Guide4.2 buildfruThe buildfru command initializes I2C bus EEPROM descriptive datastructures for the named FRU a

Strany 12

SRM Console Diagnostics 4-5The information supplied on the buildfru command line includes the consolename for the FRU, part number, serial number,

Strany 13

xi4–3 clear_error...4-104–4 deposit and examine ...

Strany 14

4-6 Compaq AlphaServer ES40 Service GuideThe ES40 FRU assembly hierarchy has three levels. The FRU types from thetop to the bottom of the hierarchy

Strany 15

SRM Console Diagnostics 4-7Arguments<fru_name>Console name for this FRU. This name reflects the positionof the FRU in the assembly hierarchy

Strany 16

4-8 Compaq AlphaServer ES40 Service Guide4.3 cat el and more elThe cat el and more el commands display the contents of the consoleevent log.In Exam

Strany 17 - Document Structure

SRM Console Diagnostics 4-9➊CPU 1 failed.➋Fan 1 and Fan 2 failed.Status and error messages are logged to the console event log at power-up,during n

Strany 18

4-10 Compaq AlphaServer ES40 Service Guide4.4 clear_errorThe clear_error command clear errors logged in the FRU EEPROMs asreported by the show erro

Strany 19 - Information on the Internet

SRM Console Diagnostics 4-114.5 crashThe SRM crash command forces a crash dump to the selected device forUNIX and OpenVMS systems.P00>>> c

Strany 20

4-12 Compaq AlphaServer ES40 Service Guide4.6 deposit and examineThe deposit command writes data to the specified address of a memorylocation, regi

Strany 21 - System Overview

SRM Console Diagnostics 4-13DepositThe deposit command stores data in the location specified. If no options aregiven, the system uses the options f

Strany 22 - System Architecture

4-14 Compaq AlphaServer ES40 Service Guide-bDefines data size as byte.-wDefines data size as word.-l (default)Defines data size as longword.-qDefin

Strany 23

SRM Console Diagnostics 4-15Symbolic forms can be used for the address. They are:pcThe program counter. The address space is set to GPR.+The locati

Strany 24 - System Enclosures

xiiFigures1–1 System Block Diagram...1-21–2 Compaq AlphaServer ES40 Systems...

Strany 25

4-16 Compaq AlphaServer ES40 Service Guide4.7 exerThe exer command exercises one or more devices by performingspecified read, write, and compare op

Strany 26 - Orientation)

SRM Console Diagnostics 4-17P00>>> ls -l dk*.*r--- dk 0/0 0 dka0.0.0.0.0P00>>> exer dk*.* -bc 1

Strany 27 - System Chassis—Rear View

4-18 Compaq AlphaServer ES40 Service Guide7. Compare buffer1 with buffer2 and report any discrepancies.8. Repeat the above steps until each block o

Strany 28 - I/O Ports and Slots

SRM Console Diagnostics 4-19-bs <block_size>Specifies the block size (hex) in bytes. The default is 200(hex).-bc <block_per_io>Specifie

Strany 29

4-20 Compaq AlphaServer ES40 Service Guide-a <action_string>(continued)• ? Seek to a random block offset within thespecified range of blocks

Strany 30 - 2 3 4 5 6

SRM Console Diagnostics 4-214.8 floppy_writeThe floppy_write script runs a write test on the floppy drive todetermine whether or not you can write

Strany 31

4-22 Compaq AlphaServer ES40 Service Guide4.9 grepThe grep command is very similar to the UNIX grep command. Itallows you to search for “regular e

Strany 32 - System Motherboard

SRM Console Diagnostics 4-23Syntaxgrep ( [-{c|i|n|v}] [-f <file>] [<expression>] [<file>...] )Arguments<expression>Specifi

Strany 33

4-24 Compaq AlphaServer ES40 Service Guide4.10 hdThe hd command dumps the contents of a file (byte stream) inhexadecimal and ASCII.Example 4–8 hd

Strany 34 - CPU Card

SRM Console Diagnostics 4-25➊Example 4–8 shows a hex dump to DPR location 2b00, ending at block 0.Syntaxhd [-{byte|word|long|quad}] [-{sb|eb} <n

Strany 35

xiii6–7 AlphaBIOS Utilities Menu...6-296–8 Run Maintenance Program Dialog Box ...

Strany 36 - Address Arrays 0 & 1

4-26 Compaq AlphaServer ES40 Service Guide4.11 infoThe info command displays registers and data structures. You canenter the command by itself or

Strany 37

SRM Console Diagnostics 4-27info 0Displays the SRM memory descriptors as described in the Alpha SystemReference Manual.info 1Displays the page tabl

Strany 38

4-28 Compaq AlphaServer ES40 Service GuideExample 4–11 shows an abbreviated info 2 display.Example 4–11 info 2P00>>> info 2GCT_BUFFER_HE

Strany 39

SRM Console Diagnostics 4-29Example 4–12 shows an abbreviated info 3 display.Example 4–12 info 3P00>>> info 3CCHIP CSRs: 8

Strany 40

4-30 Compaq AlphaServer ES40 Service GuideExample 4–13 shows an abbreviated info 4 display.Example 4–13 info 4P00>>> info 4

Strany 41 - Dual-Port RAM (DPR)

SRM Console Diagnostics 4-314.12 kill and kill_diagsThe kill and kill_diags commands terminate diagnostics that arecurrently executing.Example 4–14

Strany 42

4-32 Compaq AlphaServer ES40 Service Guide4.13 memexerThe memexer command runs a specified number of memory exercisersin the background. Nothing i

Strany 43

SRM Console Diagnostics 4-33If the memory configuration is very large, the console might not test all of thememory. The upper limit is 1 GB.Use th

Strany 44

4-34 Compaq AlphaServer ES40 Service Guide4.14 memtestThe memtest command exercises a specified section of memory.Typically memtest is run from the

Strany 45 - ➋ +5 V Auxiliary

SRM Console Diagnostics 4-35➊Use the show memory command or an info 0 command to see wherememory is located.➋Starting address➌Length of the section

Strany 46 - Figure 1–13 System Fans

xivTables1 Compaq AlphaServer ES40 Documentation...xix1–1 Fan Descriptions...

Strany 47 - Table 1–1 Fan Descriptions

4-36 Compaq AlphaServer ES40 Service GuideNOTE: If memtest is used to test large sections of memory, testing may take awhile to complete. If you is

Strany 48 - Removable Media Storage

SRM Console Diagnostics 4-37Syntaxmemtest ( [-sa <start_address>] [-ea <end_address>] [-l <length>][-bs <block_size>] [-i &

Strany 49 - Hard Disk Drive Storage

4-38 Compaq AlphaServer ES40 Service GuideOptions-mTimer. Prints out the run time of the pass. Default = off .-zTests the specified memory address

Strany 50 - System Access

SRM Console Diagnostics 4-394.15 netThe net command performs maintenance operations on a specifiedEthernet port. Net -ic initializes the MOP count

Strany 51

4-40 Compaq AlphaServer ES40 Service GuideSyntaxnet [-ic]net [-s]Arguments<port_name>Specifies the Ethernet port on which to operate, either

Strany 52 - Console Terminal

SRM Console Diagnostics 4-414.16 nettestThe nettest command tests the network ports using MOP loopback.Typically nettest is run from the built-in c

Strany 53 - Troubleshooting

4-42 Compaq AlphaServer ES40 Service GuideNettest performs a network test. It can test the ei* or ew* ports in internalloopback, external loopback,

Strany 54 - Questions to Consider

SRM Console Diagnostics 4-43Syntaxnettest ( [-f <file>] [-mode <port_mode>] [-p <pass_count>][-sv <mop_version>] [-to <l

Strany 55 - Diagnostic Tables

4-44 Compaq AlphaServer ES40 Service Guide-sv <mop_version> Specifies which MOP version protocol to use. If 3,then MOP V3 (DECNET Phase IV) p

Strany 56 - Table 2–1 Power Problems

SRM Console Diagnostics 4-454.17 set sys_serial_numThe set sys_serial_num command sets the system serial number. Thiscommand is used by Manufactur

Strany 57

xvD–11 21272-CA Device Interrupt Request Register Fields... D-30D–12 21272-CA Pchip Error Register Fields...

Strany 58

4-46 Compaq AlphaServer ES40 Service Guide4.18 show errorThe show error command reports errors logged to the FRU EEPROMs.Example 4–20 show errorP

Strany 59 - Table 2–4 Boot Problems

SRM Console Diagnostics 4-47The output of the show error command is based on information logged to theserial control bus EEPROMs on the system FRUs

Strany 60

4-48 Compaq AlphaServer ES40 Service GuideTable 4–2 Show Error Message TranslationBit Mask(E Field) Text Message Meaning and Action01<fruname&

Strany 61 - Service Tools and Utilities

SRM Console Diagnostics 4-494.19 show fruThe show fru command displays the physical configuration of FRUs.Use show fru -e to display FRUs with erro

Strany 62 - 2.3.4 AlphaBIOS Menus

4-50 Compaq AlphaServer ES40 Service GuidePWR1 00 30-49448-01. C02 2P91600530 API-7650FAN1 00 70-40073-01 -

Strany 63 - 2.3.7 Crash Dumps

SRM Console Diagnostics 4-51Table 4–3 lists bit assignments for failures that could potentially be listed in theE (error) field of the show fru com

Strany 64

4-52 Compaq AlphaServer ES40 Service Guide4.20 show_statusThe show_status command displays the progress of diagnostics. Thecommand reports one lin

Strany 65 - Information Resources

SRM Console Diagnostics 4-53➊Process ID➋The SRM diagnostic for the particular device➌The ID of the device under test➍Number of diagnostic passes th

Strany 66 - 2.4.5 Software Patches

4-54 Compaq AlphaServer ES40 Service Guide4.21 sys_exerThe sys_exer command exercises the devices displayed with the showconfig command. Tests are

Strany 67 - 2.4.7 Supported Options

SRM Console Diagnostics 4-55Use the show_status command to display the progress of diagnostic tests.The diagnostics started by the sys_exer command

Strany 69 - Power-Up Diagnostics

4-56 Compaq AlphaServer ES40 Service Guide4.22 testThe test command verifies all the devices in the system. This commandcan be used on all supporte

Strany 70

SRM Console Diagnostics 4-57• A trial diskette with files installed• A trial CD-ROM with files installedThe test script tests devices in the follow

Strany 72

Error Logs 5-1Chapter 5Error LogsThis chapter tells how to interpret error logs reported by the operating system.The following topics are covered:•

Strany 73

5-2 Compaq AlphaServer ES40 Service Guide5.1 Error Log Analysis with Compaq AnalyzeCompaq Analyze (CA) is a fault management diagnostic tool that i

Strany 74 - Power-Up Displays

Error Logs 5-35.1.1 WEB Enterprise Service (WEBES) DirectorCompaq Analyze uses the functionality contained in the WEBESDirector, a process that ex

Strany 75

5-4 Compaq AlphaServer ES40 Service Guide5.1.2 Invoking the GUIWhen you invoke the Compaq Analyze GUI, the node “localhost” opensby default for al

Strany 76

Error Logs 5-5Figure 5–2 shows an example of an event screen for an ES40 system.When an error is detected, it is reported to the console with a ser

Strany 77

5-6 Compaq AlphaServer ES40 Service Guide5.1.3 Problem Found ReportAfter you select the Problem Found report and click on DisplayInformation, a fu

Strany 78

Error Logs 5-7identification for this event type. The Event_ID_Count indicates the numberthis event is of this event type.Brief DescriptionThe Bri

Strany 79

xviiPrefaceIntended AudienceThis manual is for service providers and self-maintenance customers who areresponsible for servicing Compaq AlphaServer ES

Strany 80 - P00>>>

5-8 Compaq AlphaServer ES40 Service GuideFigure 5–4 FRU List Designator

Strany 81

Error Logs 5-9FRU ListThe FRU List designator lists the most probable defective FRUs. This listindicates that service needs to be administered to

Strany 82

5-10 Compaq AlphaServer ES40 Service GuideFigure 5–5 Evidence Designator

Strany 83

Error Logs 5-11EvidenceThe Evidence designator provides information that leads Compaq Analyze toidentify the failing FRU and its location. A porti

Strany 84

5-12 Compaq AlphaServer ES40 Service Guide5.2 Fault Detection and ReportingTable 5–1 provides a summary of the fault detection and correctioncompon

Strany 85

Error Logs 5-13Table 5–1 Compaq AlphaServer ES40 Fault Detection and CorrectionComponent Fault Detection/Correction CapabilityAlpha 21264 (EV6)mi

Strany 86

5-14 Compaq AlphaServer ES40 Service Guide5.3 Machine Checks/InterruptsThe exceptions that result from hardware system errors are calledmachine che

Strany 87 - 3.3.4 SRM Console Event Log

Error Logs 5-15Table 5–2 Machine Checks/Interrupts (Continued)Error Type Error DescriptionsSystem Correctable Error(620)ES40-specific correctable

Strany 88

5-16 Compaq AlphaServer ES40 Service Guide5.3.1 Error Logging and Event Log Entry FormatThe operating system error handlers generate several entry

Strany 89

Error Logs 5-17Table 5–3 Sample Error Log Event Structure Map (ES40 with 10 PCI Slots)OFFSET(hex) 63 56 55 48 47 40 39 32

Strany 90 - Power-Up Error Messages

xviiiThis manual has eight chapters and five appendixes.• Chapter 1, System Overview, gives an overview of the system anddescribes the components.• Ch

Strany 91

5-18 Compaq AlphaServer ES40 Service Guide5.4 Environmental Errors Captured by SRMIf an environmental error occurs while the SRM console is running

Strany 92

Error Logs 5-19P00>>>*** unexpected system event through vector 680 on CPU 0os_flags 0000000000000000cchip_dirx 00040000000000

Strany 93

5-20 Compaq AlphaServer ES40 Service Guide5.5 Windows NT Error LogsThe Display Error Frames selection of the AlphaBIOS Utilities menuallows you to

Strany 94 - 3.4.3 No MEM Error

Error Logs 5-21Fatal Error HaltsFatal error halts are single errors that occur when the operating system isrunning. Only one operating system fata

Strany 95

5-22 Compaq AlphaServer ES40 Service GuideFigure 5–7 Display Error Frames Screen

Strany 96 - 3.4.4 RMC Error Messages

Error Logs 5-23Displaying an Error Frame1. To display the error frame, enter AlphaBIOS Setup and select the Utilitiesmenu.2. From the Utilities men

Strany 97

5-24 Compaq AlphaServer ES40 Service Guide5.5.1 Viewing a Formatted Text-Style Error FramePress the Enter key to view a formatted text-style error

Strany 98 - 3.4.5 SROM Error Messages

Error Logs 5-25You can browse the entire contents of an error log by using the scroll bar, asshown in Figure 5–9.Figure 5–9 Browsing Error Logs

Strany 99

5-26 Compaq AlphaServer ES40 Service Guide5.5.2 Viewing a Binary Dump of the Error FramePress the F6 key to get a binary dump of the entire error

Strany 100 - Figure 3–2 Function Jumpers

Error Logs 5-275.5.3 Saving the Error Frame to the FloppyPress F10 to save the error frame to the floppy. For the formatted textstyle, an ASCII (

Strany 101

xixDocumentation Titles1 Compaq AlphaServer ES40 DocumentationTitle Order NumberUser Documentation KitOwner’s GuideUser Interface GuideBasic Instal

Strany 102 - Updating the RMC

5-28 Compaq AlphaServer ES40 Service GuideThe OS fatal and double error halt files are named as follows. The<cpuNumber> is two digits.Type o

Strany 103

Error Logs 5-29Number of TLVs in header 0078h 00000006hWall-Clock Time (Tag) 007ch 0041hWall-Clock Time (Length) 007eh 0028hWall-

Strany 104

5-30 Compaq AlphaServer ES40 Service Guide5.5.4 Deleting an Error FrameUse the DEL key to delete the error frame from the flash ROM. If youdelete

Strany 105 - SRM Console Diagnostics

Error Logs 5-31Figure 5–14 Deleting an Old Error Frame

Strany 107 - (Continued)

System Configuration and Setup 6-1Chapter 6System Configuration and SetupThis chapter describes how to configure and set up Compaq AlphaServer ES40

Strany 108 - Example 4–1 buildfru

6-2 Compaq AlphaServer ES40 Service Guide6.1 System ConsolesSystem console programs are located in a flash ROM on the systemmotherboard. From the

Strany 109

System Configuration and Setup 6-3SRM ConsoleSystems running the Tru64 UNIX or OpenVMS operating systems areconfigured from the SRM console, a comm

Strany 110

6-4 Compaq AlphaServer ES40 Service Guide6.1.1 Switching Between ConsolesUnder some circumstances, you may need to switch between the systemconsol

Strany 111

System Configuration and Setup 6-56.1.2 Selecting the Console and Display DeviceThe SRM os_type environment variable determines which userinterfac

Strany 112 - Example 4–2 more el

First Printing, July 1999The information in this publication is subject to change without notice.COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR T

Strany 114 - Example 4–3 clear_error

6-6 Compaq AlphaServer ES40 Service GuideYou can verify the display device with the SRM show console command andchange the display device with the

Strany 115 - UNIX and OpenVMS systems

System Configuration and Setup 6-76.1.3 Setting the Control Panel MessageIf you are running Tru64 UNIX or OpenVMS, you can create acustomized mess

Strany 116

6-8 Compaq AlphaServer ES40 Service Guide6.2 Displaying the Hardware ConfigurationView the system hardware configuration for UNIX and OpenVMSsystem

Strany 117

System Configuration and Setup 6-9Displaying a Windows NT Hardware ConfigurationView a Windows NT configuration as follows:1. From the AlphaBIOS Se

Strany 118

6-10 Compaq AlphaServer ES40 Service Guide6.3 Setting Environment Variables for Tru64 UNIX or OpenVMSEnvironment variables pass configuration infor

Strany 119

System Configuration and Setup 6-11set envarThe set command sets or modifies the value of an environment variable. It canalso be used to create a n

Strany 120 - Example 4–5 exer

6-12 Compaq AlphaServer ES40 Service GuideTable 6–1 SRM Environment Variables Used on ES40 SystemsVariable Attributes Descriptionauto_actionNV,W1

Strany 121

System Configuration and Setup 6-13Table 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descriptionbo

Strany 122

6-14 Compaq AlphaServer ES40 Service GuideTable 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descri

Strany 123

System Configuration and Setup 6-15Table 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descriptionco

Strany 124

System Overview 1-1Chapter 1System OverviewThis chapter provides an overview of the system in these sections:• System Architecture• System Enclosur

Strany 125 - Example 4–6 floppy_write

6-16 Compaq AlphaServer ES40 Service GuideTable 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descri

Strany 126 - Example 4–7 grep

System Configuration and Setup 6-17Table 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descriptionla

Strany 127

6-18 Compaq AlphaServer ES40 Service GuideTable 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attributes Descri

Strany 128 - Example 4–8 hd

System Configuration and Setup 6-19Table 6–1 SRM Environment Variables Used on ES40 Systems (Continued)Variable Attribute Descriptionsys

Strany 129 - Arguments

6-20 Compaq AlphaServer ES40 Service Guide6.4 Setting Up a System for Windows NTBefore you install and boot Windows NT for the first time, set thes

Strany 130 - Example 4–9 info 0

System Configuration and Setup 6-216.4.1 Setting the Date and TimeSet the date and time from the CMOS Setup screen.Figure 6–4 CMOS Setup ScreenD

Strany 131 - Example 4–10 info 1

6-22 Compaq AlphaServer ES40 Service Guide6.4.2 Setting Up the Hard DiskSet up the hard disk from the Hard Disk Setup screen.Figure 6–5 Hard Dis

Strany 132 - Example 4–11 info 2

System Configuration and Setup 6-236.4.3 Setting the Level of Memory TestingSet the level of memory testing that occurs when the system is powercy

Strany 133 - Example 4–12 info 3

6-24 Compaq AlphaServer ES40 Service Guide6.5 Setting Automatic BootingWindows NT systems are factory set to auto start; UNIX and OpenVMSsystems ar

Strany 134 - Example 4–13 info 4

System Configuration and Setup 6-256.5.1 Windows NT and Auto StartOn Windows NT systems the Auto Start option is enabled by default,which causes t

Strany 135

1-2 Compaq AlphaServer ES40 Service Guide1.1 System ArchitectureThe system uses a switch-based interconnect system that maintainsconstant performan

Strany 136 - Example 4–15 memexer

6-26 Compaq AlphaServer ES40 Service Guide6.5.2 Setting Tru64 UNIX or OpenVMS Systems to Auto StartThe SRM auto_action environment variable determ

Strany 137

System Configuration and Setup 6-276.6 Changing the Default Boot DeviceIt is not necessary to modify the boot file setting for Windows NT. Youcan

Strany 138 - Example 4–16 memtest

6-28 Compaq AlphaServer ES40 Service Guide6.7 Running AlphaBIOS-Based UtilitiesDepending upon the type of hardware you have, you may have to runhar

Strany 139

System Configuration and Setup 6-296.7.1 Running Utilities from a VGA MonitorIf you are running Windows NT, no terminal setup is required forrunni

Strany 140

6-30 Compaq AlphaServer ES40 Service Guide4. In the Run Maintenance Program dialog box, type the name of the programto be run in the Program Name f

Strany 141

System Configuration and Setup 6-316.7.2 Setting Up Serial ModeSerial mode requires a VT320 or higher (or equivalent) terminal. Torun AlphaBIOS a

Strany 142

6-32 Compaq AlphaServer ES40 Service Guide6.7.3 Running Utilities from a Serial TerminalUtilities are run from a serial terminal the same way as f

Strany 143

System Configuration and Setup 6-331. Issue the alphabios command at the P00>>> prompt to start theAlphaBIOS console.2. From the AlphaBIOS

Strany 144

6-34 Compaq AlphaServer ES40 Service Guide6.7.4 Running the RAID Standalone Configuration UtilityThe RAID Standalone Configuration Utility is used

Strany 145 - Example 4–18 nettest

System Configuration and Setup 6-356.8 Setting SRM SecurityThe set password and set secure commands set SRM security. Thelogin command turns off s

Strany 146

System Overview 1-3This system is designed to fully exploit the potential of the Alpha 21264 chip byusing a switch-based (or point-to-point) interc

Strany 147

6-36 Compaq AlphaServer ES40 Service Guide➊Setting a password. If a password has not been set and the set passwordcommand is issued, the console p

Strany 148

System Configuration and Setup 6-37If You Forget the PasswordIf you forget the current password, use the login command in conjunction withthe contr

Strany 149

6-38 Compaq AlphaServer ES40 Service Guide6.9 Setting Windows NT SecurityPassword protection provides two levels of security for a Windows NTsystem

Strany 150 - Example 4–20 show error

System Configuration and Setup 6-39Startup password protection provides more comprehensive protection thansetup password protection because with st

Strany 151

6-40 Compaq AlphaServer ES40 Service Guide6.10 Configuring DevicesBecome familiar with the configuration requirements for CPUs andmemory before rem

Strany 152

System Configuration and Setup 6-41Figure 6–10 CPU Slot Locations (Tower)CPU 3CPU 2CPU 1CPU 0PK0229CPU Configuration Rules6. A CPU must be instal

Strany 153 - ➊➋➌ ➍ ➎ ➏

6-42 Compaq AlphaServer ES40 Service Guide6.10.2 Memory ConfigurationBecome familiar with the rules for memory configuration beforeadding DIMMs to

Strany 154

System Configuration and Setup 6-43DIMM Information for Model 2 SystemsDIMMs are manufactured with two types of SRAMs, stacked and unstacked(see Fi

Strany 155

6-44 Compaq AlphaServer ES40 Service GuideFigure 6–12 Memory Configuration (Pedestal/Rack)11335577002244661133557700224466Array 0Sets 0 & 4Ar

Strany 156 - ➊➋➌➍➎➏ ➐

System Configuration and Setup 6-45Figure 6–13 Memory Configuration (Tower)00224466Array 0Sets 0 & 4Array 1Sets 1 & 5Array 2Sets 2 &

Strany 157

1-4 Compaq AlphaServer ES40 Service Guide1.2 System EnclosuresThe Compaq AlphaServer ES40 family consists of a standalone tower, apedestal with exp

Strany 158 - Example 4–23 sys_exer

6-46 Compaq AlphaServer ES40 Service Guide6.10.3 PCI ConfigurationFigure 6–14 PCI Slot Locations (Pedestal/Rack) 1234567891010-SlotSystem123891

Strany 159

System Configuration and Setup 6-47Figure 6–15 PCI Slot Locations (Tower)1234567891010-Slot System12 36-Slot System 8910PK0227The PCI slots are

Strany 160 - Example 4–24 test -lb

6-48 Compaq AlphaServer ES40 Service Guide6.10.4 Power Supply ConfigurationsFigure 6–16 Power Supply Locations001122TowerPedestal/RackPK0207A001

Strany 161

System Configuration and Setup 6-49The system can have the following power configurations:Single Power Supply. A single power supply is provided w

Strany 162

6-50 Compaq AlphaServer ES40 Service Guide6.11 Switching Between Operating SystemsThe system supports three operating systems. You can install Tru

Strany 163 - Error Logs

System Configuration and Setup 6-511. Shut down the operating system and power off the system. Unplug thepower cord from each power supply.2. Remo

Strany 164

6-52 Compaq AlphaServer ES40 Service Guide6.11.2 Switching from Windows NT to UNIX or OpenVMSFollow this procedure if you have already installed W

Strany 165

Using the Remote Management Console 7-1Chapter 7Using the Remote Management ConsoleYou can manage the system through the remote management console

Strany 166 - 5.1.2 Invoking the GUI

7-2 Compaq AlphaServer ES40 Service Guide7.1 RMC OverviewThe remote management console provides a mechanism for monitoringthe system (voltages, tem

Strany 167

Using the Remote Management Console 7-3The RMC logic is implemented using an 8-bit microprocessor, PIC17C44, as theprimary control device. The fir

Strany 168 - 5.1.3 Problem Found Report

System Overview 1-5Model VariantsAlphaServer ES40 systems are offered in two models. The entry-level modelprovides connectors for four DIMMs on ea

Strany 169

7-4 Compaq AlphaServer ES40 Service Guide7.2 Operating ModesThe RMC can be configured to manage different data flow pathsdefined by the com1_mode e

Strany 170

Using the Remote Management Console 7-5Through ModeThrough mode is the default operating mode. The RMC routes every characterof data between the i

Strany 171

7-6 Compaq AlphaServer ES40 Service Guide7.2.1 Bypass ModesFor modem connection, you can set the operating mode so that dataand control signals pa

Strany 172

Using the Remote Management Console 7-7Figure 7–2 shows the data flow in the bypass modes. Note that the internalsystem COM1 port is connected dir

Strany 173

7-8 Compaq AlphaServer ES40 Service GuideAfter downloading binary files, you can set the com1_mode environmentvariable from the SRM console to swit

Strany 174 - Fault Detection and Reporting

Using the Remote Management Console 7-97.3 Terminal SetupYou can use the RMC from a modem hookup or the serial terminalconnected to the system. As

Strany 175

7-10 Compaq AlphaServer ES40 Service Guide7.4 Connecting to the RMC CLIYou type an escape sequence to connect to the RMC CLI. You canconnect to t

Strany 176 - Machine Checks/Interrupts

Using the Remote Management Console 7-11Connecting from the Local VGA MonitorTo connect to the RMC CLI from the local VGA monitor, the consoleenvir

Strany 177

7-12 Compaq AlphaServer ES40 Service Guide7.5 SRM Environment Variables for COM1Several SRM environment variables allow you to set up the COM1seria

Strany 178

Using the Remote Management Console 7-137.6 RMC Command-Line InterfaceThe remote management console supports setup commands andcommands for managin

Strany 179

1-6 Compaq AlphaServer ES40 Service Guide1.3 System Chassis—Front View/Top ViewFigure 1–3 Components Top/Front View (Pedestal/Rackmount

Strany 180

7-14 Compaq AlphaServer ES40 Service GuideCommand ConventionsObserve the following conventions for entering RMC commands:• Enter enough characters

Strany 181

Using the Remote Management Console 7-157.6.1 Defining the COM1 Data FlowUse the set com1_mode command from SRM or RMC to define theCOM1 data flow

Strany 182 - AlphaServer

7-16 Compaq AlphaServer ES40 Service Guide7.6.2 Displaying the System StatusThe RMC status command displays the current RMC settings.Table 7–1 exp

Strany 183

Using the Remote Management Console 7-17Table 7–1 Status Command FieldsField MeaningOn-Chip FirmwareRevision:Revision of RMC firmware on the micr

Strany 184

7-18 Compaq AlphaServer ES40 Service Guide7.6.3 Displaying the System EnvironmentThe RMC env command provides a snapshot of the systemenvironment.

Strany 185

Using the Remote Management Console 7-19➊ CPU temperature. In this example four CPUs are present.➋Temperature of PCI backplane: Zone 0 includes PC

Strany 186

7-20 Compaq AlphaServer ES40 Service Guide7.6.4 Dumping DPR DataThe dump command dumps unformatted data from DPR locations0–3FFF hex. The informat

Strany 187 - Error Logs 5-25

Using the Remote Management Console 7-21➊DPR address➋Number of bytes dumped (in hex). In the example the dump commanddumps EF bytes from address 1

Strany 188

7-22 Compaq AlphaServer ES40 Service Guide7.6.5 Power On and Off, Reset, and HaltThe RMC power {on, off}, halt {in, out}, and reset commands perfo

Strany 189

Using the Remote Management Console 7-23Halt In and Halt OutThe halt in command halts the system. The halt out command releases thehalt. When you

Strany 190

System Overview 1-71.4 System Chassis—Rear ViewFigure 1–4 Rear Components (Pedestal/Rackmount Orientation)231PK0206➊ Power supplies➋ PCI bulkhead

Strany 191 - Error Logs 5-29

7-24 Compaq AlphaServer ES40 Service Guide7.6.6 Configuring Remote Dial-InBefore you can dial in through the RMC modem port or enable thesystem to

Strany 192

Using the Remote Management Console 7-25➊Sets the password that is prompted for at the beginning of a modemsession. The string cannot exceed 14 ch

Strany 193 - Error Logs 5-31

7-26 Compaq AlphaServer ES40 Service Guide7.6.7 Configuring Dial-Out AlertWhen you are not monitoring the system from a modem connection,you can u

Strany 194

Using the Remote Management Console 7-27The elements of the dial string and alert string are shown in Table 7–2. Pagingservices vary, so you need

Strany 195 - and Setup

7-28 Compaq AlphaServer ES40 Service GuideTable 7–2 Elements of Dial String and Alert StringDial StringATXDTThe dial string is case sensitive. T

Strany 196 - System Consoles

Using the Remote Management Console 7-297.6.8 Resetting the Escape SequenceThe RMC set escape command sets a new escape sequence.The new escape se

Strany 197

7-30 Compaq AlphaServer ES40 Service Guide7.7 Resetting the RMC to Factory DefaultsIf the non-default RMC escape sequence has been lost or forgotte

Strany 198

Using the Remote Management Console 7-31The following procedure restores the default settings:1. Shut down the operating system and press the Power

Strany 199

7-32 Compaq AlphaServer ES40 Service Guide7.8 Troubleshooting TipsTable 7–3 lists possible causes and suggested solutions for symptomsyou might se

Strany 200

Using the Remote Management Console 7-33Table 7–3 RMC Troubleshooting (Continued)Symptom Possible Cause Suggested SolutionRMC will not answerwhen

Strany 201 - Example 6–1 set ocp_text

1-8 Compaq AlphaServer ES40 Service Guide1.5 I/O Ports and SlotsFigure 1–5 Rear ConnectorsPK020991 2 3 4 5 6 781012345678910Pedestal/RackTower

Strany 203

FRU Removal and Replacement 8-1Chapter 8FRU Removal and ReplacementThis chapter describes the procedures for removing and replacing FRUs onCompaq A

Strany 204

8-2 Compaq AlphaServer ES40 Service Guide8.1 FRUsTable 8–1 lists the FRUs by part number and description. Figure 8–1shows the location of FRUs in

Strany 205

FRU Removal and Replacement 8-3Table 8–1 FRU List (Continued)Part # DescriptionCPU Modules54-30158-03 500 MHz EV6 4 MB cached CPU54-30158-05 Acc

Strany 206

8-4 Compaq AlphaServer ES40 Service GuideTable 8–1 FRU List (Continued)Part # Description30-49448-01 Power supply, 720 WattsSN-LKQ46-Ax Keyboard,

Strany 207 - (Continued)

FRU Removal and Replacement 8-58.1.1 Power CordsTower enclosures ordered in North America include a 120 V powercord. Non-North American orders re

Strany 208

8-6 Compaq AlphaServer ES40 Service Guide8.1.2 FRU LocationsFigure 8–1 and Figure 8–2 show the location of FRUs in the pedestaland rackmount confi

Strany 209

FRU Removal and Replacement 8-7Figure 8–2 FRUs — Rear (Pedestal/Rack View)PK0286PowerSuppliesPower HarnessAccess CoverSpeakerI/O Connector Module

Strany 210

8-8 Compaq AlphaServer ES40 Service Guide8.1.3 Important Information Before Replacing FRUsThe system must be shut down before you replace most FRU

Strany 211

FRU Removal and Replacement 8-9Before Replacing Non Hot-Plug FRUsFollow the procedure below before replacing any non hot-plug FRU.1. Shut down the

Strany 212

System Overview 1-9Rear Panel Connections➊Modem port—Dedicated 9-pin port for connection by modem to remotemanagement console.➋COM2 serial port—Ext

Strany 213

8-10 Compaq AlphaServer ES40 Service Guide8.2 Removing Enclosure Panels on a Tower or PedestalOpen and remove the front door. Loosen the captive s

Strany 214

FRU Removal and Replacement 8-11To Remove Enclosure Panels from a TowerThe enclosure panels are secured by captive screws.1. Remove the front door.

Strany 215

8-12 Compaq AlphaServer ES40 Service GuideFigure 8–4 Enclosure Panel Removal (Pedestal)12PK0234

Strany 216 - =Express ESC=Exit

FRU Removal and Replacement 8-13To Remove Enclosure Panels from a PedestalThe enclosure panels are secured by captive screws.1. Open and remove the

Strany 217

8-14 Compaq AlphaServer ES40 Service Guide8.3 Accessing the System Chassis in a CabinetIn a rackmount system, the system chassis is mounted to slid

Strany 218 - Setting Automatic Booting

FRU Removal and Replacement 8-15To Gain Access to the System Chassis1. Open the front door of the cabinet.2. Pull out the stabilizer bar ➊ at the b

Strany 219

8-16 Compaq AlphaServer ES40 Service Guide8.4 Removing Covers from the System ChassisThe system chassis has three covers: the fan cover, the syste

Strany 220

FRU Removal and Replacement 8-17Figure 8–7 and Figure 8–8 show the location and removal of covers on the towerand pedestal/rackmount systems, respe

Strany 221

8-18 Compaq AlphaServer ES40 Service GuideFigure 8–7 Covers on the System Chassis (Tower)PK021654312221

Strany 222

FRU Removal and Replacement 8-19Figure 8–8 Covers on the System Chassis (Pedestal/Rack)PK02151453212

Strany 223

Attention! Ceci est un produit de Classe A. Dans un environnement domestique, ceproduit risque de créer des interférences radioélectriques, il appar

Strany 224

1-10 Compaq AlphaServer ES40 Service Guide1.5 Control PanelThe control panel provides system controls and status indicators. Thecontrols are the Po

Strany 225 - 6.7.2 Setting Up Serial Mode

8-20 Compaq AlphaServer ES40 Service Guide8.5 Power SupplyFigure 8–9 Removing a Power Supply5432PK0232a1

Strany 226

FRU Removal and Replacement 8-21 WARNING: Hazardous voltages are contained within thepower supply. Do not attempt to service. Return to factory

Strany 227

8-22 Compaq AlphaServer ES40 Service Guide8.6 FansFigure 8–10 Replacing FansUnlockLock561234PK0208

Strany 228

FRU Removal and Replacement 8-23The fans are hot-plug components. You can replace individual fans while thesystem is running.WARNING: Contact wi

Strany 229 - Setting SRM Security

8-24 Compaq AlphaServer ES40 Service Guide8.7 Hard Disk DrivesFigure 8–11 Removing a Hard DrivePK0938a12

Strany 230 - Example 6–4 clear password

FRU Removal and Replacement 8-25Hard drives are hot-plug components.CAUTION: Before replacing a hard disk drive, ensure that the SCSI controllerand

Strany 231

8-26 Compaq AlphaServer ES40 Service Guide8.8 CPUsYou must shut the system down before adding or replacing a CPU.Figure 8–12 Removing CPU CardsPK

Strany 232 - Setting Windows NT Security

FRU Removal and Replacement 8-27Replacing a CPU Card1. Remove the covers from the fan area and the system card cage.2. Pull up on the clips at each

Strany 233

8-28 Compaq AlphaServer ES40 Service Guide8.9 Memory DIMMsFigure 8–13 Removing MMBs and DIMMsPK0278TowerPedestal/Rack1234231111

Strany 234 - Configuring Devices

FRU Removal and Replacement 8-29 WARNING: Memory DIMMs have parts that operate at hightemperatures. Wait 2 minutes after power is removed beforet

Strany 235

System Overview 1-11➌Power LED (green). Lights when the power button is depressed andsystem power passes initial checks.➍Reset button. A momenta

Strany 236 - 6.10.2 Memory Configuration

8-30 Compaq AlphaServer ES40 Service GuideFigure 8–14 Aligning DIMM in MMBPK0953a

Strany 237 - Stacked DIMMs

FRU Removal and Replacement 8-314. Install the new DIMM. Align the notches on the gold fingers with theconnector keys (Figure 8–14) and secure the

Strany 238

8-32 Compaq AlphaServer ES40 Service Guide8.10 PCI CardsFigure 8–15 Installing or Replacing a PCI CardPK0245231WARNING: To prevent fire, use only

Strany 239

FRU Removal and Replacement 8-33Installing or Replacing a PCI CardYou must shut the system down before adding or replacing a PCI card.1. Remove the

Strany 240 - 6.10.3 PCI Configuration

8-34 Compaq AlphaServer ES40 Service Guide8.11 OCP AssemblyFigure 8–16 Removing the OCP Assembly12PK0282

Strany 241 - 6-Slot System

FRU Removal and Replacement 8-35Removing the OCP AssemblyYou must shut the system down before removing the OCP assembly.1. Press the two tabs ➊ on

Strany 242 - 00111222

8-36 Compaq AlphaServer ES40 Service Guide8.12 Removable MediaFigure 8–17 Removing a 5.25-Inch Device12344PK0287

Strany 243

FRU Removal and Replacement 8-37Removing a 5.25-Inch Removable Media DeviceYou must shut the system down before adding or replacing a removable med

Strany 244

8-38 Compaq AlphaServer ES40 Service Guide8.13 Floppy DriveFigure 8–18 Removing the Floppy Drive123445PK0281

Strany 245

FRU Removal and Replacement 8-39Removing the Floppy DriveYou must shut the system down before removing the floppy drive.1. Remove the cover to the

Strany 246

1-12 Compaq AlphaServer ES40 Service Guide1.6 System MotherboardThe system motherboard is located on the floor of the system card cage.It has slots

Strany 247 - Management Console

8-40 Compaq AlphaServer ES40 Service Guide8.14 I/O Connector AssemblyFigure 8–19 Removing the I/O Connector AssemblyPK028421

Strany 248 - RMC Overview

FRU Removal and Replacement 8-41Removing the I/O Connector AssemblyYou must shut the system down before removing the I/O connector assembly.1. Unpl

Strany 249 - DPR Error Repository

8-42 Compaq AlphaServer ES40 Service Guide8.15 PCI BackplaneFigure 8–20 Cables Connected to PCI Backplane1 2 3 48567PK0279Connecting Cable Connec

Strany 250 - Remote Serial Terminal

FRU Removal and Replacement 8-43Disconnecting the CablesYou must shut the system down before accessing the PCI area.1. Remove the cover to the PCI

Strany 251

8-44 Compaq AlphaServer ES40 Service GuideFigure 8–21 Removing the PCI BackplanePK02803122 41

Strany 252 - 7.2.1 Bypass Modes

FRU Removal and Replacement 8-45Removing the PCI BackplaneCAUTION: When removing the PCI backplane, be careful not to flex the board.Flexing the bo

Strany 253

8-46 Compaq AlphaServer ES40 Service Guide8.16 System MotherboardFigure 8–22 Removing the System MotherboardPK12071237784465

Strany 254

FRU Removal and Replacement 8-47 !WARNING: CPUs and memory DIMMs have parts that operateat high temperatures. Wait 2 minutes after power is remov

Strany 255 - ➊ and a terminal is

8-48 Compaq AlphaServer ES40 Service Guide9. Unplug the five connectors ➏ on the bottom of the system motherboard.10. Remove the three Phillips scr

Strany 256 - Connecting to the RMC CLI

FRU Removal and Replacement 8-49After installing a new motherboard:1. Power up to the P00>>> prompt.2. Enter the clear_error all command.3

Strany 257

System Overview 1-13The system motherboard has the majority of the logic for the system, includingthe CPU, MMB connectors, the PCI connector to I/O

Strany 258

8-50 Compaq AlphaServer ES40 Service Guide8.17 Power HarnessFigure 8–23 Removing the Power Harness34651298778PK1208FrontBack

Strany 259 - RMC Command-Line Interface

FRU Removal and Replacement 8-51NOTE: Removing the power harness requires the removal of other systemFRUs. Review the removal procedures for the p

Strany 261 - Example 7–1 set com1_mode

SRM Console Commands A-1Appendix ASRM Console CommandsThis appendix lists the SRM console commands that are most frequently usedwith the Compaq Alp

Strany 262 - Example 7–2 status

A-2 Compaq AlphaServer ES40 Service GuideTable A–1 SRM Commands Used on ES40 Systems (Continued)Command FunctionexerExercises one or more devices

Strany 263 - Field Meaning

SRM Console Commands A-3Table A–1 SRM Commands Used on ES40 Systems (Continued)Command FunctionrmcInvokes the remote management console from the l

Strany 265

Jumpers and Switches B-1Appendix BJumpers and SwitchesThis chapter lists and describes the configuration jumpers and switches on thesystem motherboa

Strany 266 - 7.6.4 Dumping DPR Data

B-2 Compaq AlphaServer ES40 Service GuideB.1 RMC and SPC Jumpers on System MotherboardThe RMC jumpers can be used to override the RMC defaults. Fo

Strany 267

Jumpers and Switches B-3Table B–1 RMC/SPC Jumper SettingsJumper DescriptionJ24 1–2: Disables RMC flash update2–3: Enables RMC flash update (defaul

Strany 268 - Example 7–5 power on/off

1-14 Compaq AlphaServer ES40 Service Guide1.7 CPU CardAn AlphaServer ES40 can have up to four CPU cards. In addition to theAlpha 21264 chip, the CP

Strany 269 - Example 7–7 reset

B-4 Compaq AlphaServer ES40 Service GuideB.2 TIG/SROM Jumpers on System MotherboardTIG/SROM jumpers allow you to load the TIG if flash RAM is corru

Strany 270

Jumpers and Switches B-5Table B–2 TIG/SROM Jumper DescriptionsJumper DescriptionJ21 1–2: Load TIG from flash RAM (default)2–3: Load TIG from seria

Strany 271

B-6 Compaq AlphaServer ES40 Service GuideB.3 Clock Generator Switch SettingsSwitchpack E16 on the system motherboard sets the frequency of themain

Strany 272

Jumpers and Switches B-7Table B–3 Clock Generator SettingsSW1 M0 (on)SW2 M1 (on)SW3 M2 (on)SW4 M3 (off)SW5 M4 (on)SW6 M5 (off)SW7 M6 (on)SW8 N0 (o

Strany 273

B-8 Compaq AlphaServer ES40 Service GuideB.4 Jumpers on PCI BoardYou can set J31 on the PCI board to force DTR so that a modem will notbe disconnec

Strany 274

Jumpers and Switches B-9Table B–4 PCI Board Jumper DescriptionsJumper Description➊J31 1–2: Do not force COM1 DTR2–3: Force COM1 DTR (default)This

Strany 275 - Example 7–10 set escape

B-10 Compaq AlphaServer ES40 Service GuideB.5 Setting JumpersReview the material in the previous sections of this chapter beforesetting any system

Strany 276

DPR Address Layout C-1Appendix CDPR Address LayoutThis appendix shows the address layout of the dual-port RAM (DPR). Use theSRM examine dpr:addres

Strany 277

C-2 Compaq AlphaServer ES40 Service GuideC.1 DPR Address LayoutTable C–1 DPR Address LayoutLocation Logical Written(Hex) Indicator By Us

Strany 278 - Troubleshooting Tips

DPR Address Layout C-3Table C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used For16 SROM SROM Power O

Strany 279

System Overview 1-15The 21264 microprocessor is a superscalar CPU with out-of-order execution andspeculative execution to maximize speed and perfor

Strany 280

C-4 Compaq AlphaServer ES40 Service GuideTable C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used For81 8

Strany 281 - and Replacement

DPR Address Layout C-5Table C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used For93:96 93 RMC Temperatur

Strany 282 - Table 8–1 FRU List

C-6 Compaq AlphaServer ES40 Service GuideTable C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used ForB

Strany 283

DPR Address Layout C-7Table C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used ForFC FC RMC Co

Strany 284

C-8 Compaq AlphaServer ES40 Service GuideTable C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator

Strany 285 - 8.1.1 Power Cords

DPR Address Layout C-9Table C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used For2C00:2

Strany 286 - 8.1.2 FRU Locations

C-10 Compaq AlphaServer ES40 Service GuideTable C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator

Strany 287

DPR Address Layout C-11Table C–1 DPR Address Layout (Continued)Location Logical Written(Hex) Indicator By Used For3500:

Strany 289

Registers D-1Appendix DRegistersThis appendix describes 21264 (EV6) internal processor registers; 21272(Tsunami/Typhoon) system support chipset reg

Strany 290 - Pedestal

1-16 Compaq AlphaServer ES40 Service Guide1.8 Memory Architecture and OptionsThe system has two 256-bit wide memory data buses, which can movelarge

Strany 291 - ➋ at the top and the

D-2 Compaq AlphaServer ES40 Service GuideD.1 Ibox Status Register (I_STAT)The Ibox Status Register (I_STAT) is read only by PAL code and is aneleme

Strany 292

Registers D-3Table D–1 Ibox Status Register FieldsName Bits Type DescriptionReserved <63:31> RO Reserved for Compaq.DPE <30> W1CI-cac

Strany 293

D-4 Compaq AlphaServer ES40 Service GuideD.2 Memory Management Status Register (MM_STAT)The Memory Management Status Register (MM_STAT) is read onl

Strany 294

Registers D-5Table D–2 Memory Management Status Register FieldsName Bits Type DescriptionReserved <63:11> Reserved for Compaq.DC_TAG_PERR&l

Strany 295

D-6 Compaq AlphaServer ES40 Service GuideD.3 Dcache Status Register (DC_STAT)The Dcache Status Register (DC_STAT) is read only by PAL code and isan

Strany 296 - V @ >240VA

Registers D-7Table D–3 Dcache Status Register FieldsName Bits Type DescriptionReserved <63:5> Reserved for Compaq.SEO <4> W1CSecond e

Strany 297

D-8 Compaq AlphaServer ES40 Service GuideD.4 Cbox Read Register The Cbox Read Register is read only by PAL code and is an element inthe CPU or syst

Strany 298

Registers D-9Table D–4 Cbox Read Register Fields (Continued)Name DescriptionC_STAT<4:0>(continued)Bits Error Status01100 ISTREAM_BC_ERR0110

Strany 299

D-10 Compaq AlphaServer ES40 Service GuideD.5 Exception Address Register (EXC_ADDR)The exception address register (EXC_ADDR) is a read-only registe

Strany 300 - Power Supply

Registers D-11EXC_ADDR[0] is set if the associated exception occurred in PAL mode. Theexception actions are:• If the exception was a fault or a syn

Strany 301 - ➍ out of the system

System Overview 1-17Memory ArchitectureMemory throughput in this system is maximized by the following features:• Two independent, wide memory data

Strany 302 - Figure 8–10 Replacing Fans

D-12 Compaq AlphaServer ES40 Service GuideD.6 Interrupt Enable and Current Processor Mode Register (IER_CM)The interrupt enable and current process

Strany 303 - ➊,➋,➌, and ➍)

Registers D-13Table D–5 IER_CM Register FieldsName Extent Type DescriptionReserved [63:39]EIEN[5:0] [38:33] RW External Interrupt EnableSLEN [32

Strany 304 - Hard Disk Drives

D-14 Compaq AlphaServer ES40 Service GuideD.7 Interrupt Summary Register (ISUM)The interrupt summary register (ISUM) is a read-only register thatre

Strany 305

Registers D-15Table D–6 ISUM Register FieldsName Extent Type DescriptionReserved [63:39]EI[5:0] [38:33] RO External InterruptsSL [32] RO Serial L

Strany 306

D-16 Compaq AlphaServer ES40 Service GuideD.8 PAL Base Register (PAL_BASE)The PAL base register (PAL_BASE) is a read-write register thatcontains th

Strany 307

Registers D-17Table D–7 PAL_BASE Register FieldsName Extent Type DescriptionReserved [63:44] RO, 0 Reserved for COMPAQ.PAL_BASE[43:15] [43:15] RW

Strany 308 - Memory DIMMs

D-18 Compaq AlphaServer ES40 Service GuideD.9 Ibox Control Register (I_CTL)The Ibox control register (I_CTL) is a read-write register that controls

Strany 309

Registers D-19Table D–8 I_CTL Register FieldsName Extent Type DescriptionSEXT(VPTB[47]) [63:48] RW,0 Sign extended VPTB[47].VPTB[47:30] [47:30] R

Strany 310

D-20 Compaq AlphaServer ES40 Service GuideTable D–8 I_CTL Register Fields (Continued)Name Extent Type DescriptionPCT0_EN [18] RW,0 Enable perform

Strany 311 - Verification — SRM Console

Registers D-21Table D–8 I_CTL Register Fields (Continued)Name Extent Type DescriptionSL_XMIT [13] WOWhen set, drives a value on SromClk_H.HWE [12

Strany 312

1-18 Compaq AlphaServer ES40 Service Guide1.9 PCI BackplaneThe PCI backplane has two independent 64-bit, 33 MHz PCI buses thatsupport 64-bit PCI sl

Strany 313 - ➋ into the connector

D-22 Compaq AlphaServer ES40 Service GuideTable D–8 I_CTL Register Fields (Continued)Name Extent Type DescriptionSPE[2:0] [5:3] RW,0 Super Page M

Strany 314 - OCP Assembly

Registers D-23D.10 Process Context Register (PCTX)The process context register (PCTX) contains information associatedwith the context of a process.

Strany 315

D-24 Compaq AlphaServer ES40 Service GuideThe following table lists the correspondence between IPR index bits and registerfields.IPR Index Bit Regi

Strany 316

Registers D-25Table D–9 PCTX Register FieldsName Extent Type DescriptionReserved [63:47]ASN[7:0] [46:39] RW Address space number.Reserved [38:13]

Strany 317

D-26 Compaq AlphaServer ES40 Service GuideD.11 21272-CA Cchip Miscellaneous Register (MISC)This register is designed so that only writes of 1 affec

Strany 318 - Floppy Drive

Registers D-27Table D–10 21272-CA Cchip Miscellaneous Register FieldsName Bits TypeInitialState DescriptionRES <63:44> MBZ, RAZ 0 Reserved.

Strany 319

D-28 Compaq AlphaServer ES40 Service GuideTable D–10 21272-CA Cchip Miscellaneous Register Fields (Continued)Name Bits TypeInitialState

Strany 320 - I/O Connector Assembly

Registers D-29D.12 21272-CA Cchip CPU Device Interrupt Request Register (DIRn, n=0,1,2,3)These registers indicate which interrupts are pending to t

Strany 321

D-30 Compaq AlphaServer ES40 Service GuideTable D–11 21272-CA Device Interrupt Request Register FieldsName Bits TypeInitialState DescriptionERR &

Strany 322 - PCI Backplane

Registers D-31D.13 21272-CA Pchip Error Register (PERROR)If any bits <11:0> are set, this register is frozen. Only bit <0> can be sett

Strany 323

System Overview 1-19PCI Bus Implementation• Is fully compliant with the PCI Version 2.1 Specification• Operates at 33 MHz, delivering a peak bandwi

Strany 324

D-32 Compaq AlphaServer ES40 Service GuideAccess RW635655525150032PK1419-9931 4344 43 40 3916 15 12 11 8910 7 5621RESCREUECCRESNDSRDPETAAPESGEDCRTO

Strany 325

Registers D-33Table D–12 21272-CA Pchip Error Register FieldsName Bits TypeInitialState DescriptionSYN <63:56> RO 0 ECC syndrome of error i

Strany 326

D-34 Compaq AlphaServer ES40 Service GuideTable D–12 21272-CA Pchip Error Register Fields (Continued)Name Bits TypeInitialState DescriptionRES &l

Strany 327 - ➊, if present

Registers D-35D.14 21272-CA Array Address Registers (AAR0–AAR3)The Array Address Registers define the base address and size for eachmemory array.Ta

Strany 328

D-36 Compaq AlphaServer ES40 Service GuideTable D–13 21272-CA Array Address Register (AAR) (Continued)Field Bits Type Init DescriptionRES<7:4&

Strany 329

Registers D-37D.15 DPR Registers for 680 Correctable Machine Check Logout FramesDPR Locations A0:A9 represent the information that the console will

Strany 330 - Power Harness

D-38 Compaq AlphaServer ES40 Service GuideTable D–14 DPR Locations A0:A9 (Continued)DPRLocation DescriptionA2 If bit is set the associated fault

Strany 331

Registers D-39Table D–14 DPR Locations A0:A9 (Continued)DPRLocation DescriptionA6 These bits indicate a door has been opened.Bit 0 unused 1

Strany 332

D-40 Compaq AlphaServer ES40 Service GuideD.16 DPR Power Supply Status RegistersThe RMC reads nine bytes of information from each of the three powe

Strany 333 - SRM Console Commands

Registers D-41D.17 DPR 680 Fatal RegistersThe RMC is powered by an auxiliary 5V supply that is independentfrom the system power subsystem. When an

Strany 335 - SRM Console Commands A-3

1-20 Compaq AlphaServer ES40 Service Guide1.10 Remote System Management LogicThe remote system management logic consists of two major elements:the

Strany 336

D-42 Compaq AlphaServer ES40 Service GuideD.18 CPU and System Uncorrectable Machine Check Logout FrameThe SRM console or the Windows NT HAL builds

Strany 337 - Jumpers and Switches

Registers D-43D.19 Console Data Log Event Environmental Error Logout Frame (680 Uncorrectable)Compaq Analyze uses the logout frame in Table D–18 fo

Strany 338

D-44 Compaq AlphaServer ES40 Service GuideD.20 CPU and System Correctable Machine Check Logout FrameThe SRM console or the Windows NT HAL builds th

Strany 339

Registers D-45D.21 Environmental Error Logout Frame(680 Correctable)Table D–20 shows Environ_QW_1:7 and Environ_QW_8 error statecapture information

Strany 340 - Figure B–2 TIG/SROM Jumpers

D-46 Compaq AlphaServer ES40 Service GuideD.22 Platform Logout Frame Register TranslationCompaq Analyze uses information from all logout frames for

Strany 341

Registers D-47Table D–21 Bit Definition of Logout Frame RegistersRegisterIdentification Bit Field Text Translation DescriptionC_SYNDROME_0 <7:

Strany 342

D-48 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Tr

Strany 343

Registers D-49Table D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Translation DescriptionI_STAT

Strany 344 - Jumpers on PCI Board

D-50 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Tr

Strany 345

Registers D-51Table D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Translation DescriptionI_CTL &

Strany 346 - Setting Jumpers

System Overview 1-21Dual-Port RAM (DPR)The ES40 system features a dual-port RAM—RAM that is shared between theRMC and the system motherboard logic—

Strany 347 - DPR Address Layout

D-52 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)ID Bit Field Text Translation Descriptio

Strany 348

Registers D-53Table D–21 Bit Definition of Logout Frame Registers (Continued)ID Bit Field Text Translation DescriptionDIRx <63><62>&l

Strany 349

D-54 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Tr

Strany 350

Registers D-55Table D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Translation DescriptionSMIR(En

Strany 351

D-56 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Tr

Strany 352

Registers D-57Table D–21 Bit Definition of Logout Frame Registers (Continued)RegisterIdentification Bit Field Text Translation DescriptionSystem_

Strany 353

D-58 Compaq AlphaServer ES40 Service GuideTable D–21 Bit Definition of Logout Frame Registers (Continued)Register Identification Bit Field Text T

Strany 354

Isolating Failing DIMMs E-1Appendix EIsolating Failing DIMMsThis appendix explains how to manually isolate a failing DIMM from the failingaddress a

Strany 355

E-2 Compaq AlphaServer ES40 Service GuideE.1 Information for Isolating FailuresTable E–1 lists the information needed to isolate the failure. SeeA

Strany 356

Isolating Failing DIMMs E-3E.2 DIMM Isolation ProcedureUse the procedure in this section to isolate the failing DIMM.1. Find the failing array by u

Strany 357

1-22 Compaq AlphaServer ES40 Service Guide1.10.1 System Power Controller (SPC)The System Power Controller (SPC) is responsible for sequencing thet

Strany 358

E-4 Compaq AlphaServer ES40 Service Guide3. After finding the real array, determine whether it is the lower array set orthe upper array set. Use D

Strany 359 - Registers

Isolating Failing DIMMs E-54. Use the following table to determine the proper set. Bits<27,28,29,30,31,32>are from the failing address.Config

Strany 360 - Ibox Status Register (I_STAT)

E-6 Compaq AlphaServer ES40 Service GuideTable E–4 Failing DIMM Lookup Table Array 1 Array 2 Array 3 Array 4Data Upper

Strany 361

Isolating Failing DIMMs E-7Table E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array 4Data Upper

Strany 362 - (MM_STAT)

E-8 Compaq AlphaServer ES40 Service GuideTable E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array

Strany 363

Isolating Failing DIMMs E-9Table E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array 4Data Upper

Strany 364 - TPERR_P0

E-10 Compaq AlphaServer ES40 Service GuideTable E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Arra

Strany 365

Isolating Failing DIMMs E-11Table E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array 4Data Upper

Strany 366 - Cbox Read Register

E-12 Compaq AlphaServer ES40 Service GuideTable E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Arra

Strany 367

Isolating Failing DIMMs E-13Table E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array 4Data Upper

Strany 368 - PC[31:2]

System Overview 1-231.10.2 Remote Management Console (RMC)The remote management console (RMC) provides a mechanism forremotely monitoring a system

Strany 369

E-14 Compaq AlphaServer ES40 Service GuideTable E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Arra

Strany 370 - Register (IER_CM)

Isolating Failing DIMMs E-15Table E–4 Failing DIMM Lookup Table (Continued) Array 1 Array 2 Array 3 Array 4Check Upper

Strany 371

E-16 Compaq AlphaServer ES40 Service GuideE.3 EV6 Single-Bit ErrorsThe procedure for detection down to the set of DIMMs for a single-biterror is ve

Strany 372

Isolating Failing DIMMs E-17Table E–5 Syndrome to Data Check Bits Table (Continued)Syndrome C_Syndrome 0 C_Syndrome 131 Data Bit 14 or 142 Data B

Strany 373

E-18 Compaq AlphaServer ES40 Service GuideTable E–5 Syndrome to Data Check Bits Table (Continued)Syndrome C_Syndrome 0 C_Syndrome 1B0 Data Bit 46

Strany 374 - PAL Base Register (PAL_BASE)

Index-1IndexAAAR memory addresses, E-2Acceptance testing, 2-11Advanced CMOS Setup screen, 6-23Alpha System Reference Manual, 4-26alphabios command, 6-

Strany 375 - Name Extent Type Description

Index-2com1_baud environment variable, 6-14com1_flow environment variable, 6-14com1_mode environment variable, 6-14, 7-4COM2 and parallel portloopback

Strany 376 - Ibox Control Register (I_CTL)

Index-3grep, 4-22hd, 4-24info, 4-26kill, 4-31kill_diags, 4-31memexer, 4-32memtest, 4-34more el, 4-8net, 4-39net -ic, 4-39net -s, 4-39nettest, 4-41set

Strany 377 - Continued on next page

Index-4Error logs, 5-1browsing in AlphaBIOS, 5-25Windows NT, 5-20Error messagespower-up, 3-22RMC, 3-28SROM, 3-30, 3-31Error repository, clearing, 8-1,

Strany 378

Index-5Internal processor registers (21264), D-1Interrupts, 5-14Invoking SRM from AlphaBIOS, 6-4JJumpersPCI, B-8RMC and SPC, B-2setting, B-10TIG/SROM,

Strany 379 - Registers D-21

1-24 Compaq AlphaServer ES40 Service Guide1.11 Power SuppliesThe power supplies provide power to components in the system box.The number of power s

Strany 380

Index-6Operating systemserrors reported by, 2-8switching between, 6-50switching to UNIX or OpenVMS, 6-52switching to Windows NT, 6-50Operator control

Strany 381 - Registers D-23

Index-7Registers (21272) DIRn, D-29Registers (EV6)Cbox Read, D-8DC_STAT, D-6EXC_ADDR, D-10I_CTL, D-18I_STAT, D-2IER_CM, D-12ISUM, D-14MM_STAT, D-4PAL_

Strany 382

Index-8show boot* command, 6-8show config command, 6-8show console command, 6-6show device command, 6-8show envar command, 6-11show error command, 4-4

Strany 383 - Registers D-25

Index-9UUART ports, 7-5Updating RMC, 3-34USB ports, 1-9User interfaces, 6-2UtilitiesAlphaBIOS, 6-28running from serial terminal, 6-32running from VGA,

Strany 385

System Overview 1-25One to three power supplies provide power to components in the system box.The system supports redundant power configurations to

Strany 386 - (Continued)

1-26 Compaq AlphaServer ES40 Service Guide1.12 FansThe system has six hot-plug fans that provide front-to-back airflow.Figure 1–13 System Fans561

Strany 387 - Register (DIRn, n=0,1,2,3)

System Overview 1-27The system fans are shown in Figure 1–13 and described in Table 1–1.Table 1–1 Fan DescriptionsFanNumberArea Cooled Fan Failur

Strany 388

1-28 Compaq AlphaServer ES40 Service Guide1.13 Removable Media StorageThe system box houses a CD-ROM drive ➊ and a high-density 3.5-inchfloppy disk

Strany 389

System Overview 1-291.14 Hard Disk Drive StorageThe system chassis can have either one or two storage disk cages.You can install four 1.6-inch hard

Strany 390 - Access RW

vContentsPreface xviiChapter 1 System Overview1.1 System Architecture...1-2

Strany 391 - RAZ Rev0

1-30 Compaq AlphaServer ES40 Service Guide1.15 System AccessAt the time of delivery, the system keys are taped inside the small frontdoor that prov

Strany 392

System Overview 1-31Both the tower and pedestal systems have a small front door through which thecontrol panel and removable media devices are acce

Strany 393

1-32 Compaq AlphaServer ES40 Service Guide1.16 Console TerminalThe console terminal can be a serial (character cell) terminalconnected to the COM1

Strany 394

Troubleshooting 2-1Chapter 2TroubleshootingThis chapter describes the starting points for diagnosing problems on CompaqAlphaServer ES40 systems. Th

Strany 395 - Check Logout Frames

2-2 Compaq AlphaServer ES40 Service Guide2.1 Questions to ConsiderBefore troubleshooting any system problem, first check the sitemaintenance log fo

Strany 396

Troubleshooting 2-32.2 Diagnostic TablesSystem problems can be classified into the following five categories.Using these categories, you can quickl

Strany 397

2-4 Compaq AlphaServer ES40 Service GuideTable 2–1 Power ProblemsSymptom Action ReferenceSystem does notpower on.• Check error messages on the OC

Strany 398

Troubleshooting 2-5Table 2–2 Problems Getting to Console ModeSymptom Action ReferencePower-up screen is notdisplayed at systemconsole.Note any er

Strany 399 - DPR 680 Fatal Registers

2-6 Compaq AlphaServer ES40 Service GuideTable 2–3 Problems Reported by the ConsoleSymptom Action ReferenceNo SRM messages aredisplayed after the

Strany 400 - Check Logout Frame

Troubleshooting 2-7Table 2–4 Boot ProblemsSymptom Action ReferenceSystem cannot findboot device.Check the system configuration for thecorrect dev

Strany 401

vi2.3.4 AlphaBIOS Menus...2-102.3.5 Remote Management Console (RMC)...

Strany 402 - Logout Frame

2-8 Compaq AlphaServer ES40 Service GuideTable 2–5 Errors Reported by the Operating SystemSymptom Action ReferenceSystem is hung, butSRM console

Strany 403 - (680 Correctable)

Troubleshooting 2-92.3 Service Tools and UtilitiesThis section lists some of the tools and utilities available for acceptancetesting and diagnosis

Strany 404

2-10 Compaq AlphaServer ES40 Service Guide2.3.4 AlphaBIOS MenusThe AlphaBIOS Standard CMOS Setup menu and the Advanced CMOS Setupmenu are used to

Strany 405 - Registers D-47

Troubleshooting 2-112.3.6 Operating System Exercisers (DEC VET)The Verifier and Exerciser Tool (DEC VET) is supported by the Tru64 UNIX,OpenVMS, a

Strany 406

2-12 Compaq AlphaServer ES40 Service Guide2.3.9 StorageWorks Command Console (SWCC)The StorageWorks Command Console (SWCC) is a storage management

Strany 407 - Registers D-49

Troubleshooting 2-132.4 Information ResourcesMany information resources are available, including tools that can bedownloaded from the Internet, fir

Strany 408

2-14 Compaq AlphaServer ES40 Service Guide• If you do not have a Web browser, you can download the files usinganonymous ftp:ftp.digital.com/pub/Dig

Strany 409 - Registers D-51

Troubleshooting 2-152.4.6 Late-Breaking Technical InformationYou can download up-to-date files and late-breaking technical information fromthe Int

Strany 411 - Registers D-53

Power-Up Diagnostics and Display 3-1Chapter 3Power-Up Diagnosticsand DisplayThis chapter describes the power-up process and RMC, SROM, and SRM powe

Strany 412

vii4.7 exer...4-164.8 floppy_write...

Strany 413 - Registers D-55

3-2 Compaq AlphaServer ES40 Service Guide3.1 Overview of Power-Up DiagnosticsThe power-up process begins with the power-on of the power supplies.Af

Strany 414

Power-Up Diagnostics and Display 3-33.2 System Power-Up SequenceThe power-up sequence is described below and illustrated inFigure 3–1.1. When the p

Strany 415 - Registers D-57

3-4 Compaq AlphaServer ES40 Service GuideFigure 3–1 Power-Up SequenceOCP Power button = INTurn on power supplies Turn on CPU converters Turn on V

Strany 416

Power-Up Diagnostics and Display 3-5Figure 3–1 Power-Up Sequence (Continued)Test PCIRelease CPUsB-Cache TestsMemory Config and TestsPK0964SROM Po

Strany 417 - Isolating Failing DIMMs

3-6 Compaq AlphaServer ES40 Service Guide3.3 Power-Up DisplaysPower-up information is displayed on the operator control panel andon the console ter

Strany 418

Power-Up Diagnostics and Display 3-7• Section 3.3.1 describes the SROM power-up sequence and shows the SROMpower-up messages and corresponding OCP

Strany 419 - DIMM Isolation Procedure

3-8 Compaq AlphaServer ES40 Service Guide3.3.1 SROM Power-Up DisplayExample 3–1 Sample SROM Power-Up DisplaySROM Power-Up Display OCP MessageSRO

Strany 420

Power-Up Diagnostics and Display 3-9SROM Power-Up Sequence➊When the system powers up, the SROM code is loaded into the I-cache(instruction cache) o

Strany 421

3-10 Compaq AlphaServer ES40 Service Guide3.3.2 SRM Console Power-Up DisplayWhen SROM power-up is complete, the primary CPU transfers controlto th

Strany 422

Power-Up Diagnostics and Display 3-11SRM Power-Up Sequence➊The primary CPU prints a message indicating that it is running the console.Starting with

Strany 423

viii6.4.1 Setting the Date and Time...6-216.4.2 Setting Up the Hard Disk...

Strany 424

3-12 Compaq AlphaServer ES40 Service GuideExample 3–2 SRM Power-Up Display (Continued)entering idle loopinitializing keyboardstarting console on

Strany 425

Power-Up Diagnostics and Display 3-13SRM Power-Up Sequence (Continued)➎The console is started on the secondary CPUs. The example shows a four-proc

Strany 426

3-14 Compaq AlphaServer ES40 Service Guide3.3.3 Resizing SRM Console HeapThe SRM console allocates enough memory for most configurations. Ifoptio

Strany 427

Power-Up Diagnostics and Display 3-15Example 3–3 Memory Resize Crash/Reboot Cycleinitialized idle PCBinitializing semaphoresinitializing heapinit

Strany 428

3-16 Compaq AlphaServer ES40 Service Guide 2048 MB of System MemoryTesting the SystemCPU0: insufficient dynamic memory for a request of 4592 by

Strany 429

Power-Up Diagnostics and Display 3-17SYSFAULT CPU0 - pc = 0014faacexception context saved starting at 001FD7B0GPRs: 0: 00000000 00048FF8 16: 0000

Strany 430

3-18 Compaq AlphaServer ES40 Service Guide...bus 0, slot 15 -- dqb—Acer Labs M1543C IDEstarting driversentering idle loopinitializing keyboardstart

Strany 431

Power-Up Diagnostics and Display 3-193.3.4 SRM Console Event LogThe SRM console event log helps you troubleshoot problems that do notprevent the s

Strany 432 - EV6 Single-Bit Errors

3-20 Compaq AlphaServer ES40 Service Guide3.3.5 AlphaBIOS Startup ScreensIf the system is running the Windows NT operating system, the SRMconsole

Strany 433

Power-Up Diagnostics and Display 3-21Example 3–6 AlphaBIOS Boot Screen AlphaBIOS 5.68Please select the operating system t

Strany 434

ixChapter 8 FRU Removal and Replacement8.1 FRUs ...

Strany 435

3-22 Compaq AlphaServer ES40 Service Guide3.4 Power-Up Error MessagesError messages at power-up may be displayed by the RMC, SROM, andSRM. A few S

Strany 436

Power-Up Diagnostics and Display 3-23A few SROM error messages that appear on the operator control panel areannounced by audible error beep codes,

Strany 437

3-24 Compaq AlphaServer ES40 Service Guide3.4.2 Checksum ErrorIf Jump to Console is the last message displayed on the OCP, theconsole firmware may

Strany 438

Power-Up Diagnostics and Display 3-25 ***** Loadable Firmware Update Utility *****➏-------------------------------------------------------

Strany 439

3-26 Compaq AlphaServer ES40 Service Guide3.4.3 No MEM ErrorIf the SROM code cannot find any usable memory, a 1-3-3 beep code isissued (one beep,

Strany 440

Power-Up Diagnostics and Display 3-27➊Indicates failed DIMMs. M identifies the MMB; D identifies the DIMM. Inthis line, DIMM 2 on MMB1 failed.➋In

Strany 441 - SCSI breakouts, 1-9

3-28 Compaq AlphaServer ES40 Service Guide3.4.4 RMC Error MessagesTable 3–2 lists the fatal error messages that could potentially bedisplayed on t

Strany 442

Power-Up Diagnostics and Display 3-29Table 3–3 RMC Warning MessagesMessage MeaningPSn failedPower supply failed. “n” is 0, 1, or 2.OverTemp Warn

Strany 443

3-30 Compaq AlphaServer ES40 Service Guide3.4.5 SROM Error MessagesThe SROM power-up identifies errors that may or may not prevent thesystem from

Strany 444

Power-Up Diagnostics and Display 3-31Table 3–4 SROM Error Messages (Continued)Code SROM Message OCP Message7E Configuration error on CPU #2 CfgER

Komentáře k této Příručce

Žádné komentáře

Electrolux EWF11294BW manuels

Manuels d'utilisation et guides de l'utilisateur pour Non Electrolux EWF11294BW.
Nous fournissons des manuels en pdf 3 Electrolux EWF11294BW à télécharger gratuitement par type de document : Manuel de l'utilisateur, Manuel d'installation


Electrolux EWF11294BW Manuel d'installation (4 pages)


marque: Electrolux | Catégorie: No info | Taille: 2.13 MB |

 

Table des matières





Plus de produits et de manuels pour Non Electrolux

Modèles Type de document
EKG603102X Manuel de l'utilisateur    Electrolux EKG603102X User Manual, 90 pages
ERN3011FOW Manuel de l'utilisateur   Electrolux ERN3011FOW Manuel utilisateur [pt] , 24 pages
EN3401AOX Manuel de l'utilisateur      Electrolux EN3401AOX Uživatelský manuál, 76 pages
ER8497BX Manuel de l'utilisateur   Electrolux ER8497BX Ohjekirja, 16 pages
EW8F7660P9 Manuel de l'utilisateur Electrolux EW8F7660P9 Brukermanual, 40 pages
ERN2201AOW Manuel de l'utilisateur     Electrolux ERN2201AOW Kasutusjuhend, 44 pages
EN3201AOW Manuel de l'utilisateur Electrolux EN3201AOW Användarmanual, 24 pages
EOB63300X Manuel de l'utilisateur   Electrolux EOB63300X Kasutusjuhend, 40 pages
EK276BNEEV Manuel de l'utilisateur    Electrolux EK276BNEEV Manuel utilisateur, 44 pages
EWS105417A Manuel de l'utilisateur   Electrolux EWS105417A Руководство пользователя [en] , 24 pages
ESF6281 Manuel de l'utilisateur   Electrolux ESF6281 Kullanım kılavuzu, 48 pages
ERC37300S8 Manuel de l'utilisateur   Electrolux ERC37300S8 Руководство пользователя, 16 pages
EN3452JOX Manuel de l'utilisateur      Electrolux EN3452JOX Kasutusjuhend, 64 pages
EWM1046CDU Manuel de l'utilisateur    Electrolux EWM1046CDU Пайдаланушы нұсқаулығы, 72 pages
ENN92801BW Manuel de l'utilisateur    Electrolux ENN92801BW Пайдаланушы нұсқаулығы, 64 pages
EN3853AOX Manuel de l'utilisateur      Electrolux EN3853AOX Uživatelský manuál, 84 pages
EOB53100W EU ENV06 Manuel de l'utilisateur   Electrolux EOB53100W EU ENV06 Посібник користувача [et] [fr] , 64 pages
ERN3213AOW Manuel de l'utilisateur     Electrolux ERN3213AOW Kasutusjuhend [kk] [ru] [ua] , 56 pages
ESF6510LIW Manuel de l'utilisateur   Electrolux ESF6510LJX Brugermanual, 64 pages
ENA38415X Manuel de l'utilisateur   Electrolux ENA38415X Uživatelský manuál [pt] , 48 pages