Compaq 3200 Specifikace Strana 31

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 211
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 30
2-11
Compaq Smart Array 3200 Controller Reference Guide
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: C-CH02.DOC Last Saved On: 12/7/98 8:33 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Controller 1 Controller 2
ID5 ID5
ID4 ID4
ID3 d ID3
ID2 c ID2 z
ID1 b Array A ID1 y Array A
ID0 a ID0 x
Figure 2-5. Failed arrays removed; arrays on separate controllers
To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:
IMPORTANT: These steps must be followed AS DESCRIBED. Any deviation
or mistake could result in the loss of all data across all moved arrays.
1. Power-down the system.
2. Move the array back to its original controller but retain its drive position
from the consolidated configuration.
3. Power-up the system.
4. Each controller will indicate a 1789 POST message, “Drives are
Missing.” Press F2 to fail the missing drives.
5. Run the Array Configuration Utility and remove the appropriate failed
arrays.
6. Reboot the system.