Front Panel Operation
5-28
Channel information will be displayed.
Press ENT on the drive channel you
wish the ID changed.
Press or to selectSet SCSI
Channel Pri. Ctlr ID..”, then press
ENT.
Press or to select a new ID, then
press ENT for two seconds to confirm.
Setting a SCSI Channel’s Secondary ID - Drive Channel
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit SCSI Channels," then
press ENT.
Channel information will be displayed.
Press ENT on the drive channel you
wish the ID changed.
Press or to selectSet SCSI
Channel Sec. Ctlr ID..”, then press
ENT.
Press or to select a new ID, then
press ENT for two seconds to confirm.
Setting Channel Bus Terminator
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit SCSI Channels," then
press ENT.
Channel information will be displayed.
Press or to select a channel. Press
ENT on a channel you wish the
terminator mode changed.
Press or to selectSet SCSI
Channel Terminator,” then press ENT.
View and Edit
SCSI Channels
View and Edit
SCSI Channels
CH1=Drive PID=7
SID=NA SXF=80.0M
CH1=Drive PID=7
SID=NA SXF=20.0M
CH0=Host PID=0
SID=NA SXF=20.0M
Set SCSI Channel
Pri. Ctlr ID ..
Set SCSI Channel
Sec. Ctlr ID ..
Set SCSI Channel
Terminator ..
Set Pri. Ctlr
ID= 7 to ID: 8 ?
Set Sec. Ctlr
ID=NA to ID: 9 ?