Compaq External RAID Controller & Subsystem Uživatelský manuál Strana 135

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 347
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 134
Infortrend
7-16
Adding a Global Spare Drive
A global spare replaces the failed drive in any logical drive of a
RAID system.
Move cursor bar to the SCSI drive that is not a member drive or a
spare (usually indicated as a "New Drive"), and then press
[ENTER]. Choose “Add Global Spare Drive.” When prompted to
“Add Global Spare Drive?”, choose Yes.
7.9 Viewing and Editing Logical Drive and
Drive Members
Choose “View and Edit Logical Drives” in the main menu. The array
status will be displayed. Refer to the previous chapter for more
details on the legends used in Logical Drive’s Status. To see the
drive member information, choose the logical drive by pressing
[ENTER].
Choose “View SCSI Drives.” Drive member information will be
displayed on the screen.
Zobrazit stránku 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 346 347

Komentáře k této Příručce

Žádné komentáře