Verifying component failure
Before replacing the controller, cache module, or battery pack:
Check the contr
oller LCD display panel for error messages.
Record any failure LEDs or LCD panel messages for reference purposes.
Check the controller heartbeat LED (1).IftheLEDisnotblinking,itmightindicateafailure.
Check the cont
roller fault LED (2) . If the LED is on, it might indicate a failure.
1
2
15512
Removing the controller
1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precautions.
2. Review all controller-specic warnings, cautions, and preparation procedures as detailed in Before
you begin.
3. In all single-controller congurations, power off the MSA as instructed in Removing power from
the MSA.
4. In operational dual-controller congurations, access an MSA management utility, such as the
MSA Command Line Interface (MSA-CLI) or the Array Conguration Utility (ACU) and disable the
controller being removed. For instructions, see online help. (During this procedure, because one of
the two controllers is being removed, the MSA operates in a non-redundant mode.)
5. Press the controller thumb latch and rotate the latch handle out (1).
6. Pull the controller straight out of the chassis (2).
2
1
15594
maintenance and service guide
77
Zobrazit stránku 76