Compaq AF602A - IP Console Switch Rychlé specifikace Strana 1

Procházejte online nebo si stáhněte Rychlé specifikace pro Servery Compaq AF602A - IP Console Switch. Compaq AF602A - IP Console Switch QuickSpecs [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Front View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
Support for NC375T PCI Express Quad Port Gigabit Server Adapter
At A Glance
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Processors
:
Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache
Intel® 5520 Chipset
Memory
:
Up to 12 DIMM slots
Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz when
fully populated at 2 DIMMs per Channel in 12 slots
Up to 96GB, using PC3-10600R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully populated at 2
DIMMs per Channel in 12 slots.
Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully
populated at 2 DIMMs per Channel in 12 slots
NOTE:
Half DIMM slots are available when one processor is installed.
Internal Drive Support
:
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
DA - 13248 Worldwide QuickSpecs — Version 12 — 11.25.2009
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - QuickSpecs

Front View:Rear View:1.Access panel1.Redundant Power Supply Bay (Optional)2.Front LED Indicators2.Power Supply Cable Socket3.Power on/off3.Low Profile

Strany 2

ProLiant 100-series G6 servers can use the same SNMP based InsightManagement Agents supported by other ProLiant servers. As a result,administrators ca

Strany 3

NOTE: For additional information, please see:http://h18004.www1.hp.com/products/servers/management/toolkit/index.htmlSubscriber's ChoiceSubscribe

Strany 4

Server Power CordsOne 6' Highline (IEC-IEC) power cord ships standardNOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (

Strany 5

Operating Systems andVirtualization SoftwareSupport for ProLiantServersMicrosoft Windows ServerMicrosoft Windows Server Hyper-VRed Hat Enterprise Linu

Strany 6

Factory Express Portfoliofor Servers and StorageHP Factory Express offers configuration, customization, integration and deployment services for HP ser

Strany 7

http://h20219.www2.hp.com/services/us/en/warranty/carepack-servers-proliant.htmlQuickSpecsHP ProLiant DL180 Generation 6Standard FeaturesDA - 13248

Strany 8

NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL180 G6 under the Cluster Platformproduct portfolio. These hig

Strany 9

Four Drive Serial ATA (SATA) ModelsNOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of a

Strany 10

Twelve Drive Serial ATA (SATA) ModelsNOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488234-B21)HP DL180G6 E

Strany 11

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Strany 12

Support for up to twenty-five (25) SFF with a Smart Array controller.Support for up to fourteen (14) LFF with a Smart Array controller:Hot Plug Serial

Strany 13

MemoryRegistered RDIMMsHP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP 8GB 2Rx4

Strany 14

Step 3: Choose Additional Factory Integratable Options (only one from each list unlessotherwise noted)Rear DVD KitHP DL180G6 Rear DVD Cage KitNOTE: Th

Strany 15

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additionalinformation.Unique OptionsHP

Strany 16

MemoryRegistered RDIMMsHP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP 8GB 2Rx4

Strany 17

HP 146GB 3G SAS 15K 3.5" DP ENT HDD384854-B21NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000

Strany 18

CommunicationsHP NC112T PCIe Gigabit Server Adapter503746-B21HP NC360T PCI Express Dual Port Gigabit Server Adapter412648-B21HP NC364T PCI Express Qua

Strany 19

Remote ManagementHP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7Technical Support and UpdatesNOTE: For additional License

Strany 20

SecurityHP Trusted Platform Module Option Kit488069-B21Storage ControllersSAS Controllers HP Smart Array P800 HP Smart Array P800/512 BBWC Controller3

Strany 21

HP SC08Ge Host Bus AdapterNOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/qu

Strany 22

HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape AutoloaderAK377AHP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS

Strany 23

system.Redundancy:Fully redundant non-hot plug fans (Optional)Hot plug power supply with optional redundancyPower Sources:Dual Common Slot Bay for Rig

Strany 24

StorageWorks OptionsStorageWorks Fibre Channel HBANOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For detai

Strany 25

Uninterruptible PowerSystemsHP Tower UPS HP T1000v Uninterruptible Power System HP T1000v UPSNOTE: The T1000v is available in China and India only.AF4

Strany 26

HP Rack OptionsHP KVM Switch Options2x1x16 IP Console Switch with Virtual MediaAF601A4x1x16 IP Console Switch with Virtual MediaAF602A2x16 Server Cons

Strany 27

Service and SupportOfferings (HP Care PackServices)Hardware Services 4-Hour On-site Service13-Hour x 5-Day Coverage, 3 Years, ElectronicUH271E24-Hour

Strany 28

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6Standard Memory (depending on model)4 GB

Strany 29

DIMM Type ->Registered DIMMS (RDIMMs)Unbuffered with ECCDIMMs (UDIMMs)DIMM Rank ->Dual Rank (2R)Quad Rank (4R)Single Rank(1R)Dual Rank(2R)DIMM C

Strany 30

CPU1 CPU2 slot #population orderslot #population order Chnl 11D: empty1D: emptyChnl 12A: 2GB DIMM2A: empty Chnl 23E: empty3E: emptyChnl 24

Strany 31

CPU1 CPU2 slot #population orderslot #population order Chnl 11D: 2GB DIMM1D: emptyChnl 12A: 2GB DIMM2A: empty Chnl 23E: 2GB DIMM3E: emptyC

Strany 32

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool:www.hp.com/go/ddr3memory-configuratorMemo

Strany 33

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Strany 34

http://h18004.www1.hp.com/products/servers/platforms/warranty/index.htmlQuickSpecsHP ProLiant DL180 Generation 6OverviewDA - 13248 Worldwide QuickSp

Strany 35

500GB 3G SATA 7.2K250GB 3G SATA 7.2KUp to 14 with 12drive cage +Rear Drive Cage1-14HP Smart Array P212/Zero Memory ControllerHP Smart Array P212/256 M

Strany 36

SAS Hot Plug SFF Enterprise (ENT) Drives QuantitySupportedPositionSupportedController600GB 6G 15K450GB 6G 15K450GB 3G SAS 15K30GB 6G 15K300GB 3G SAS 1

Strany 37

LTO-4 Ultrium 1840DAT 40DAT 72DAT 1601U Rack-Mount Kit3U Rack-Mount Kit Tape Drives, Internal USBDAT 40 USBDAT 72 USBDAT 160 USBDAT 320 USB1U US

Strany 38

RDX500 D2D Backup Systemsnetwork attach, iSCSID2D2500iD2D4000iRack mountEmbedded Network ControllerN/AQuickSpecsHP ProLiant DL180 Generation 6St

Strany 39

HP 460W Power SupplyPart Number - AC 460W PSU503296-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal Input Voltage (V

Strany 40

System UnitDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)Weight(approximate)Maximum(all hard dr

Strany 41

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange i

Strany 42

HP 160GB 3G SATA7.2K 3.5" ETY HDD458945-B21160GB 7,200 rpmCapacity160,041MBHeight1.04 in (26.4 mm)Width4.36 in (110.7 mm)Depth7.25 in (184.2 mm)I

Strany 43

Smart Array P410/410iControllerDisk Drive and EnclosureInterface6Gb/s SAS (Serial Attached SCSI)3Gb/s SATA (Serial ATA)SAS Connectors2 internal (Mini-

Strany 44

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryIntegrated Models&qu

Strany 45

Network ControllerHP NC362i Integrated Dual Port Gigabit Server AdapterExpansion SlotsSlot NumberBus SpeedBus Number*DeviceNumber**Hot Plug(Y/N)Notes1

Strany 46

Storage Controller4HDD ModelsHP Embedded SATA RAID Controller (integrated into the south-bridge)supporting SW RAID 0,1,10NOTE: Transfer rate up to 3.0

Strany 47

InterfacesNetwork RJ-45 (Ethernet)2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights Out100i Remote Management)Serial1Graphics1USB5

Strany 48

HP Insight Control suites include one year of 24 x 7 HP Software TechnicalSupport and Update Service ensuring rapid access to HP support staff andproa