Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Servisní příručka Strana 135

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 422
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 134
[2] 65536 4
[3] 0
[4] 65536
4
[5] 0
[6] 0
[7] 0
}
(dbx) p rm_adapters[1]->rmp_prail_va->rmc_size
5
{
[0] 16384
6
[1] 0
[2] 16384
6
[3] 0
[4] 16384
6
[5] 0
[6] 0
[7] 0
}
1 Find the size of a logical rail.
2 The logical rail is operating at 128 MB (16384 eight-KB pages).
3 Verify the jumper settings for the member systems on the first physical
rail.
4 The J3 jumper is set at 512 MB for nodes 0, 2, and 4 on the first physical
rail (65536 eight-KB pages).
5 Verify the jumper settings for the member systems on the second
physical rail.
6 The J3 jumper is set at 128 MB for nodes 0, 2, and 4 on the second
physical rail (16384 eight-KB pages).
Setting Up the Memory Channel Cluster Interconnect 5–19