Compaq BL20p - ProLiant - G2 Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Barebones pro PC / pracovní stanice Compaq BL20p - ProLiant - G2. Compaq BL20p - ProLiant - G2 Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Part Number 316078-001

HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide March 2003 (First Edition) Part Number 316078-001 HP CONFIDENTIAL Coden

Strany 2

Illustrated Parts Catalog ProLiant BL20p G2 Server Blade Components System Exploded View Figure 1-1: System exploded view 1-2 HP ProLiant BL20p Gen

Strany 3 - Contents

Illustrated Parts Catalog Server Blade Spare Parts List Table 1-1: Server Blade Spare Parts List Item Description Spare Part Number Mechanical Com

Strany 4

Illustrated Parts Catalog 1-4 HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide HP CONFIDENTIAL Codename: StormX Part Numb

Strany 5 - List of Tables

2 Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for system components. After co

Strany 6 - About This Guide

Removal and Replacement Procedures WARNING: To reduce the risk of injury from high current electrical energy, do not remove the server blade access

Strany 7

Removal and Replacement Procedures WARNING: To reduce the risk of shock or injury from high current electrical energy, do not reach into a server b

Strany 8 - Telephone Numbers

Removal and Replacement Procedures Server Blade Components Use the procedures in this section to perform service events on ProLiant BL20p G2 server bl

Strany 9 - Illustrated Parts Catalog

Removal and Replacement Procedures Figure 2-1: Pressing the Power On/Standby button CAUTION: After you press the release button, the server blade

Strany 10 - System Exploded View

Removal and Replacement Procedures CAUTION: Always populate server blade enclosure bays with either a server blade or server blade blank. Operating

Strany 11

Removal and Replacement Procedures Hard Drive Blanks To remove a hard drive blank: 1. Press the release buttons simultaneously (1). 2. Pull the blan

Strany 12

© 2003 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Intel is a U.S. reg

Strany 13 - Safety Considerations

Removal and Replacement Procedures Hot-Plug SCSI Hard Drives To assess hard drive status, observe the hot-plug SCSI hard drive status LEDs. For a deta

Strany 14 - Rack Warnings and Cautions

Removal and Replacement Procedures DIMMs To remove a DIMM: 1. Power down the server blade and remove it from the server blade enclosure. Refer to the

Strany 15 - Symbols on Equipment

Removal and Replacement Procedures Processors, Heatsinks, and PPMs To remove a processor: 1. Power down the server blade and remove it from the serve

Strany 16 - Server Blade Components

Removal and Replacement Procedures 5. Raise the locking lever to release the processor (1), and remove the processor (2). Figure 2-8: Removing the

Strany 17

Removal and Replacement Procedures CAUTION: After the cover is removed, do not touch the thermal interface media. Touching the thermal interface me

Strany 18 - Access Panel

Removal and Replacement Procedures Battery-Backed Write Cache Enabler To remove the Battery-Backed Write Cache Enabler: 1. Power down the server blad

Strany 19 - Hard Drive Blanks

Removal and Replacement Procedures 4. Remove the Battery-Backed Write Cache Enabler from the Smart Array 5i Plus Controller module. Figure 2-12: Rem

Strany 20 - Hot-Plug SCSI Hard Drives

Removal and Replacement Procedures 6. Disconnect the cable from the bottom of the Smart Array 5i Plus Controller module. Figure 2-14: Disconnecting

Strany 21 - Figure 2-6: Removing a DIMM

Removal and Replacement Procedures Fan Assembly To remove the fan assembly: 1. Power down the server blade and remove it from the server blade enclos

Strany 22

Removal and Replacement Procedures 4. Press the fan retention tab (1), and lift up the assembly (2). Figure 2-17: Removing a fan assembly Reverse s

Strany 23

Contents About This Guide Audience Assumptions...

Strany 24 - Figure 2-10: Removing a PPM

Removal and Replacement Procedures Smart Array 5i Plus Controller Module To remove the Smart Array 5i Plus Controller module: 1. Power down the serve

Strany 25 - Enabler cable

Removal and Replacement Procedures NIC Modules To remove either the standard NIC module or the dual-port Fibre Channel Mezzanine Card: 1. Power down

Strany 26

Removal and Replacement Procedures Dual Port Fibre Channel Mezzanine Card An optional dual port Fibre Channel (FC) Mezzanine Card enables Fibre Channe

Strany 27

Removal and Replacement Procedures SCSI Backplane To remove the SCSI backplane: 1. Power down the server blade and remove it from the server blade en

Strany 28 - Fan Assembly

Removal and Replacement Procedures 8. Remove the plastic fan baffle (1), and disconnect the SCSI backplane cable from the system board (2). NOTE: T

Strany 29

Removal and Replacement Procedures Power Button/LED Board To remove the power button/LED board: 1. Power down the server blade and remove it from th

Strany 30

Removal and Replacement Procedures 7. Tilt the front edge of the power button/LED board down until the keyholes on the rear of the board clear the al

Strany 31 - NIC Modules

Removal and Replacement Procedures CAUTION: Batteries, battery packs, and accumulators should not be disposed of along with general household waste

Strany 32 - located at

Removal and Replacement Procedures System Board To remove the system board: 1. Power down the server blade and remove it from the server blade enclos

Strany 33 - SCSI Backplane

Removal and Replacement Procedures 11. Loosen the system board thumbscrews. Note that the thumbscrew between the VHDM connector and the DC filter mod

Strany 34

Contents Chapter 3 Diagnostic Tools ProLiant BL p-Class Diagnostic Tools ...

Strany 35 - Power Button/LED Board

Removal and Replacement Procedures 14. Lift the edge of the system board nearest the system switches. The edge of the system board nearest the Smart

Strany 36 - Battery

Removal and Replacement Procedures HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide 2-29 HP CONFIDENTIAL Codename: Part

Strany 37

3 Diagnostic Tools ProLiant BL p-Class Diagnostic Tools Use the following tools to diagnose problems, test hardware, and monitor and manage system ope

Strany 38 - System Board

Diagnostic Tools Table 3-1: Diagnostic Tools continued Tool Description How to run the tool HP Diagnostics HP Diagnostics tests and verifies opera

Strany 39

Diagnostic Tools HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide 3-3 HP CONFIDENTIAL Codename: StormX Part Number: 00000

Strany 40

4 Connectors, LEDs, and Switches Connectors ProLiant BL20p G2 Server Blade Front Panel Connectors The server blade has one front panel connector, a di

Strany 41 - Server Blade Blanks

Connectors, LEDs, and Switches Rear Panel Connectors Use Figure 4-2 and Table 4-1 to identify ProLiant BL20p G2 server blade rear panel connectors. F

Strany 42 - Diagnostic Tools

Connectors, LEDs, and Switches System Board Components and Connectors Use Figure 4-3 and Table 4-2 to identify ProLiant BL20p G2 system board componen

Strany 43

Connectors, LEDs, and Switches Table 4-2: System Board Components and Connectors continued Item Description 14 SCSI backplane board connector 15 P

Strany 44

Connectors, LEDs, and Switches LEDs Use the following section to identify LEDs on the following ProLiant BL p-Class system components: • • ProLiant B

Strany 45 - Connectors

Contents 2-27 Loosening the system board thumbscrews... 2-27 2-2

Strany 46

Connectors, LEDs, and Switches Table 4-4: ProLiant BL20p G2 Server Blade Front Panel LEDs Item LED Description Status 1 Unit identification Blue

Strany 47

Connectors, LEDs, and Switches Table 4-5: Hot-Plug SCSI Hard Drive LEDs 1 Activity 2 Online 3 Fault Means On Off Off Do not remove the drive. Rem

Strany 48 - Diagnostic Cable

Connectors, LEDs, and Switches Switches Use the following sections to identify the locations and functions of push-button and system switches. Buttons

Strany 49

Connectors, LEDs, and Switches System Switches System switches enable you to change certain settings or to perform advanced diagnostic procedures. The

Strany 50

Connectors, LEDs, and Switches NMI Switch Crash dump analysis is an essential part of eliminating reliability problems such as hangs or crashes in op

Strany 51

Connectors, LEDs, and Switches — Press the Power On/Standby button on the front of the server blade. — Use the virtual power button feature in the i

Strany 52 - Switches

Connectors, LEDs, and Switches 4-12 HP ProLiant BL20p Generation 2 Server Blade Maintenance and Service Guide HP CONFIDENTIAL Codename: StormX Par

Strany 53 - System Switches

Index configurations, clearing the system configuration 4-10 A connectors access panel diagnostic cable 4-4 removing 2-6 fan assembly 4-3 rep

Strany 54

Index L guides HP ProLiant BL p-Class System Setup and Installation Guide 3-2 LEDs hot-plug SCSI hard drive 4-6 HP Servers Troubleshooting Guide

Strany 55

Index S processor, spare part number 1-3 ProLiant Essentials Rapid Deployment Pack SCSI backplane access 3-3 part number 1-3 description 3-3 r

Strany 56

About This Guide This maintenance and service guide can be used for reference when servicing HP ProLiant BL20p Generation 2 server blades. WARNING:

Strany 57

Index U ROMPaq 3-2 Survey Utility 3-2 unit identification (UID), LEDs 4-6 utilities V Diagnostics 3-2 Insight Manager 7 3-2 ventilation clea

Strany 58

About This Guide CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the ser

Strany 59

About This Guide Where to Go for Additional Help In addition to this guide, the following information sources are available: • HP ProLiant BL p-Class

Strany 60

1 Illustrated Parts Catalog This chapter provides illustrated parts and spare parts lists for the HP ProLiant BL20p Generation 2 server blade componen

Komentáře k této Příručce

Žádné komentáře